Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/30 ▾
← Slings & Hitches

Chapter 5 · Lesson 2 of 4

Chemicals and heat

1 min read

OSHA 1910.184 sets a mirror-image rule for synthetic web slings. Nylon is not used where fumes, vapors, sprays, mists or liquids of acids or phenolics are present, because acid attacks the nylon fiber. Polyester and polypropylene are not used where caustics are present, and web slings with aluminum fittings are kept away from caustics too.

Remember it as a pair: nylon is the acid problem, polyester is the caustic problem. Example: a pickling line uses acid baths, so a polyester web sling is the right synthetic there; a cleaning tank with caustic solution next door would call for nylon, without aluminum fittings.

Heat damage is cumulative. Synthetic fibers soften and lose strength before they visibly fail, and melting or charring anywhere on the surface is a removal condition, so a web sling worked above its tag temperature range comes out of service rather than being derated by the rigger.

Alloy chain is more tolerant, but not immune: above a moderate service temperature its working load is reduced by the amount the manufacturer specifies, severe heat retires it, and quenching hot chain in water does not restore it; rapid cooling can make the links more brittle. Heat questions always end the same way: retire or reselect, never guess a derating.

Check yourself

1. Caustic solutions are present at a work area. Which sling should be kept out of that area?

2. A steel fitting must be lifted where acid fumes and mists are present. Which synthetic web sling is the correct selection for that environment?

Facts checked 2026-11-15 · Sources: OSHA 29 CFR 1910.184: Slings, OSHA 29 CFR 1926.251: Rigging equipment for material handling, NCCCO: Rigger Level I written exam outline

Rigger Level I (NCCCO) cheat sheet: every key fact on one page →