  1. Load Assessment & Job Scope
  2. Standards & Regulations
  3. Sling Inspection & Removal
  4. Hardware & Device Inspection
  5. Slings & Hitches
  6. Rigging Hardware & Lifting Devices
  7. Load Control & Completing the Lift

Chapter 1

Load Assessment & Job Scope

Key takeaways

Common trap

  • Wrong answers often sound practical: use the biggest slings on hand, pick it a few inches and read the indicator, or round the estimate up. Each one sizes the rigging without a known weight, which is exactly what the rule forbids. → Knowing the weight of the load
  • Distractors often limit who may stop a lift to the operator or to someone under the hook. The stop signal is obeyed no matter who gives it, because the person who sees the problem is often not the person in charge. → Hands, body position and the authority to stop

Chapter 2

Standards & Regulations

Key takeaways

Common trap

Quick reference

Which ASME B30 volume covers what →
VolumeCovers
B30.5Mobile and locomotive cranes
B30.9Slings: chain, wire rope, metal mesh, fiber rope, web, roundslings
B30.10Hooks, including load block and sling hooks
B30.20Below-the-hook devices: lifting beams, spreaders, clamps, magnets, vacuum lifters
B30.26Detachable hardware: shackles, links, rings, eyebolts, hoist rings, turnbuckles, wire rope clips

Chapter 3

Sling Inspection & Removal

Key takeaways

Common trap

  • Removed from service is physical. A rejected sling left in the rack with a chalk mark, or kept in the gang box for light loads, will be picked up by the next person. It is taken out of the work area and tagged out or destroyed. → Who inspects slings, and how often
  • Many distractors offer a halfway fix: tape the cut, derate to half, mark it choker only. None of these appears in either standard. A listed removal condition takes the sling out of use until a qualified person evaluates it, and some conditions, like an exposed roundsling core, are never repaired. → Web slings, roundslings and fiber rope

Quick reference

Wire rope slings: broken wires, wear and heat →
ConditionASME B30.9OSHA 1910.184
Abrasion or scrapingMore than 5 percent off the nominal rope diameterOne-third of the outside wire diameter
Fiber core heat limit180 degrees F200 degrees F

Chapter 4

Hardware & Device Inspection

Key takeaways

Common trap

  • When a part is sound but its marking is gone, distractors suggest stamping it by hand, derating it to half, or waiting for the next periodic inspection. Missing or illegible identification is by itself a removal condition. → Eyebolts, hoist rings, links and turnbuckles

Quick reference

Hook removal criteria →
ConditionASME B30.10OSHA 1910.184
Throat opening5 percent increase, not over 1/4 inMore than 15 percent, at the narrowest point
TwistAny visibly apparent bend or twistMore than 10 degrees

Chapter 5

Slings & Hitches

Key takeaways

Common trap

  • A double-wrap choker does not double the capacity or turn the hitch into a basket. Answers that claim extra capacity from wrapping, twisting or hammering a choke down are wrong. → Choosing and rating the hitch

Quick reference

Matching the sling type to the load →
Load or settingBest fitWhy
Hot surfaces, sharp unfinished edgesAlloy chainNot cut like fiber, keeps strength where synthetics melt
Rough, abrasive bar stockMetal meshWears slowly and conforms to the load
Polished or painted finishSynthetic roundsling or webSoft body spreads the bearing area
Heat beyond a fiber core rope's tagA sling rated for that heatThe core degrades unseen

Chapter 6

Rigging Hardware & Lifting Devices

Key takeaways

Common trap

  • The shackle and eyebolt items are built to swap readings. A 30 percent shackle reduction on 10 tons leaves 7 tons, while a 30 percent eyebolt allowance on 4,000 lb leaves only 1,200 lb. Ask whether the chart says reduce by or reduce to before you multiply. → Hooks, eyebolts and swivel hoist rings

Chapter 7

Load Control & Completing the Lift

Key takeaways

Common trap

  • The most common wrong answer is the simple share: 4,000 lb for an 8,000 lb load on two legs, ignoring the angle. The opposite slip is multiplying the whole weight by the factor without dividing by the legs first. → Sling angles and leg tension

Quick reference

Sling angles and leg tension →
Angle from horizontalLoad angle factor
90 degrees1.000
60 degrees1.155
45 degrees1.414
30 degrees2.000