Rigger Level I (NCCCO) Cheat Sheet: Key Facts
Every key takeaway and common trap from the Rigger Level I (NCCCO) study guide on one page, grouped by chapter. Tap a lesson link to read the full explanation.
44 facts · 7 chaptersFacts checked 2026-11-15
Chapter 1
Load Assessment & Job Scope
Key takeaways
- Load weight comes from a documented source such as a data plate, shipping papers, drawings or a calculation, never from an eyeball estimate. → Knowing the weight of the load
- If the weight cannot be established, the rigging cannot be sized and the lift waits. → Knowing the weight of the load
- Attachment points must be designed for lifting, straddle the center of gravity and sit above it. → Center of gravity and attachment points
- The travel path is walked before the lift, and people stay out of the fall zone and out of pinch points. → The travel path, clearances and the fall zone
- Anyone who sees an unsafe condition may stop the lift, and every hazard found goes to the lift supervisor before the pick. → Hands, body position and the authority to stop
Common trap
- Wrong answers often sound practical: use the biggest slings on hand, pick it a few inches and read the indicator, or round the estimate up. Each one sizes the rigging without a known weight, which is exactly what the rule forbids. → Knowing the weight of the load
- Distractors often limit who may stop a lift to the operator or to someone under the hook. The stop signal is obeyed no matter who gives it, because the person who sees the problem is often not the person in charge. → Hands, body position and the authority to stop
Chapter 2
Standards & Regulations
Key takeaways
- B30.9 covers slings, B30.10 hooks, B30.20 below-the-hook devices, B30.26 rigging hardware and B30.5 the mobile crane itself. → Which ASME B30 volume covers what
- OSHA 1926.251 governs construction rigging and 1910.184 governs slings in general industry. → The OSHA rigging rules: 1926.251 and 1910.184
- The rated load on the item's own identification is the limit, and missing or unreadable identification takes the item out of use. → What the identification must show
- Job or shop hooks and links on alloy chain, knots in place of splices and makeshift shortening are prohibited, and custom lifting accessories are proof tested to 125 percent. → Makeshift gear and practices the rules forbid
- Hoisting people is a last resort, limited to 50 percent of rated capacity with a 125 percent, five-minute proof test at each jobsite. → Hoisting people under OSHA 1926.1431
Common trap
- On clip questions, the U-bolt on the live end is the classic wrong answer. The U crushes what it grips, so it goes on the dead end, never on the part of the rope that carries the load. → Makeshift gear and practices the rules forbid
Quick reference
| Volume | Covers |
|---|---|
| B30.5 | Mobile and locomotive cranes |
| B30.9 | Slings: chain, wire rope, metal mesh, fiber rope, web, roundslings |
| B30.10 | Hooks, including load block and sling hooks |
| B30.20 | Below-the-hook devices: lifting beams, spreaders, clamps, magnets, vacuum lifters |
| B30.26 | Detachable hardware: shackles, links, rings, eyebolts, hoist rings, turnbuckles, wire rope clips |
Chapter 3
Sling Inspection & Removal
Key takeaways
- Construction rigging is inspected before use on each shift, and under both 1926.251 and 1910.184 a competent person inspects slings each day before use. → Who inspects slings, and how often
- A designated person inspects and reports, but only a qualified person decides whether a deficiency is a hazard. → Who inspects slings, and how often
- Wire rope comes out at ten random broken wires in one lay or five in one strand in one lay. → Wire rope slings: broken wires, wear and heat
- Heat limits differ by material and by document: 180 degrees F (ASME) or 200 degrees F (OSHA) for fiber core rope, 194 degrees F (ASME) or 180 degrees F (OSHA) for nylon and polyester, 1,000 degrees F for alloy chain. → Web slings, roundslings and fiber rope
- Exposed roundsling core yarns, knots in web, and damaged load-bearing splices retire a synthetic sling. → Web slings, roundslings and fiber rope
Common trap
- Removed from service is physical. A rejected sling left in the rack with a chalk mark, or kept in the gang box for light loads, will be picked up by the next person. It is taken out of the work area and tagged out or destroyed. → Who inspects slings, and how often
- Many distractors offer a halfway fix: tape the cut, derate to half, mark it choker only. None of these appears in either standard. A listed removal condition takes the sling out of use until a qualified person evaluates it, and some conditions, like an exposed roundsling core, are never repaired. → Web slings, roundslings and fiber rope
Quick reference
| Condition | ASME B30.9 | OSHA 1910.184 |
|---|---|---|
| Abrasion or scraping | More than 5 percent off the nominal rope diameter | One-third of the outside wire diameter |
| Fiber core heat limit | 180 degrees F | 200 degrees F |
Chapter 4
Hardware & Device Inspection
Key takeaways
- Under ASME B30.10 a hook comes out at a 5 percent throat increase capped at 1/4 in, any visible twist, or more than 10 percent wear in the bowl. → Hook removal criteria
- OSHA 1910.184 uses 15 percent throat opening at the narrowest point and 10 degrees of twist, so read which document the question names. → Hook removal criteria
- A shackle with a substitute bolt, a crack, more than 10 percent wear or a pin that will not seat is out of service. → Inspecting shackles and their pins
- Illegible markings, arc strikes, weld spatter and unauthorized welding are removal conditions for all rigging hardware. → Eyebolts, hoist rings, links and turnbuckles
- Below-the-hook devices show their rated load on the structure or an attached tag, and custom lifting accessories are proof tested to 125 percent. → Lifting devices, blocks and who inspects
Common trap
- When a part is sound but its marking is gone, distractors suggest stamping it by hand, derating it to half, or waiting for the next periodic inspection. Missing or illegible identification is by itself a removal condition. → Eyebolts, hoist rings, links and turnbuckles
Quick reference
| Condition | ASME B30.10 | OSHA 1910.184 |
|---|---|---|
| Throat opening | 5 percent increase, not over 1/4 in | More than 15 percent, at the narrowest point |
| Twist | Any visibly apparent bend or twist | More than 10 degrees |
Chapter 5
Slings & Hitches
Key takeaways
- Chain suits hot loads and rough edges, metal mesh suits abrasive loads, and synthetic slings suit finished surfaces. → Matching the sling type to the load
- Nylon is kept away from acids, while polyester, polypropylene and aluminum fittings are kept away from caustics. → Chemicals and heat
- A choker is rated below vertical and drops further when the choke angle is under about 120 degrees. → Choosing and rating the hitch
- The full basket value needs vertical legs, a balanced load and an adequate D/d. → Choosing and rating the hitch
- Slings are never knotted, bolted or kinked, never pulled from under a resting load, and are stored clean and dry off the ground. → Handling, protecting and storing slings
Common trap
- A double-wrap choker does not double the capacity or turn the hitch into a basket. Answers that claim extra capacity from wrapping, twisting or hammering a choke down are wrong. → Choosing and rating the hitch
Quick reference
| Load or setting | Best fit | Why |
|---|---|---|
| Hot surfaces, sharp unfinished edges | Alloy chain | Not cut like fiber, keeps strength where synthetics melt |
| Rough, abrasive bar stock | Metal mesh | Wears slowly and conforms to the load |
| Polished or painted finish | Synthetic roundsling or web | Soft body spreads the bearing area |
| Heat beyond a fiber core rope's tag | A sling rated for that heat | The core degrades unseen |
Chapter 6
Rigging Hardware & Lifting Devices
Key takeaways
- Shackles are loaded in the bow, with multiple legs at an included angle of no more than 120 degrees. → Using shackles correctly
- Read each chart's heading: a 30 percent shackle reduction leaves 70 percent, while a 30 percent eyebolt rating is all that remains. → Hooks, eyebolts and swivel hoist rings
- Only shoulder eyebolts, seated flush with at least 1.5 diameters of thread in steel, may take an angled pull. → Hooks, eyebolts and swivel hoist rings
- If a lever hoist will not move the load with normal effort, stop and find out why; never add a cheater bar. → Turnbuckles, swivels, blocks and hoists
- A jack lifts but does not hold: the raised load is blocked and cribbed before anyone reaches under it. → Clamps, beams, gantries, rollers and jacks
Common trap
- The shackle and eyebolt items are built to swap readings. A 30 percent shackle reduction on 10 tons leaves 7 tons, while a 30 percent eyebolt allowance on 4,000 lb leaves only 1,200 lb. Ask whether the chart says reduce by or reduce to before you multiply. → Hooks, eyebolts and swivel hoist rings
Chapter 7
Load Control & Completing the Lift
Key takeaways
- A suspended load always settles with its center of gravity directly under the hook. → Finding and using the center of gravity
- Leg tension equals the weight divided by the number of legs, times the load angle factor. → Sling angles and leg tension
- Sling angles under 30 degrees from horizontal are not used without approval from the sling maker or a qualified person. → Sling angles and leg tension
- Lift a few inches, stop and check, and land and re-rig if the load does not hang level. → A smooth start and the trial lift
- Land on blocking that carries the load and leaves room to pull the slings by hand, and never drag a sling from under a resting load. → Landing the load and finishing the lift
Common trap
- The most common wrong answer is the simple share: 4,000 lb for an 8,000 lb load on two legs, ignoring the angle. The opposite slip is multiplying the whole weight by the factor without dividing by the legs first. → Sling angles and leg tension
Quick reference
| Angle from horizontal | Load angle factor |
|---|---|
| 90 degrees | 1.000 |
| 60 degrees | 1.155 |
| 45 degrees | 1.414 |
| 30 degrees | 2.000 |