Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/30 ▾
← Hardware & Device Inspection

Chapter 4 · Lesson 4 of 4

Lifting devices, blocks and who inspects

1 min read

ASME B30.20 requires a below-the-hook device's rated load to be marked on its main structure or on a tag securely attached to it, so the capacity is read at the device, not hunted for in the office.

Where a lifter is built of detachable parts, each part carries its own rating, and a lifter with a missing or illegible marking comes out of service.

Special custom-design grabs, hooks and clamps must be marked with their safe working load and proof tested to 125 percent of it before use under OSHA 1926.251(a)(4). Example: a one-off clamp rated 3 tons is tested at 3.75 tons.

Gripping and rolling parts get their own checks. A plate clamp holds by biting the plate, so rounded or packed cam and jaw teeth are a removal condition. A block with a cracked sheave flange or a groove worn oversize comes out, because the rope can jump or flatten.

Under OSHA 1910.184 the daily inspection of a sling with its fastenings and attachments is made by a competent person designated by the employer; ASME calls that tier a designated person. Free rotation, legible markings and a rope that matches the size marked on a block are what an inspector wants to find, not reasons to reject it.

Check yourself

1. Under OSHA 29 CFR 1926.251, a special custom-designed lifting clamp must be marked with its safe working load and proof tested to what level?

2. Under ASME B30.20, how must the rated load of a below-the-hook lifting device be shown?

Facts checked 2026-11-15 · Sources: OSHA 29 CFR 1926.251: Rigging equipment for material handling, OSHA 29 CFR 1910.184: Slings, NCCCO: Rigger Level I written exam outline

Rigger Level I (NCCCO) cheat sheet: every key fact on one page →