Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/30 ▾
← Hardware & Device Inspection

Chapter 4 · Lesson 1 of 4

Hook removal criteria

1 min read

A hook that has spread or twisted has already been loaded past its yield point, so the allowances are small. The exam likes to put the ASME and OSHA figures side by side, and the stem's named document decides which one is right. Where both apply, the tighter ASME figure is the practical limit:

ConditionASME B30.10OSHA 1910.184
Throat opening5 percent increase, not over 1/4 inMore than 15 percent, at the narrowest point
TwistAny visibly apparent bend or twistMore than 10 degrees

ASME B30.10 also removes a hook when wear in the bowl, or saddle, exceeds 10 percent of the original section dimension, because the saddle carries the bending load.

Measure against the original or catalog dimension, not against a neighboring worn spot. Where a latch is required, a bent, missing or inoperative latch takes the hook out of service until it is fixed.

The latch carries no load, but its job is to keep a slack sling in the bowl, and a latch that will not close cannot do that.

Example: a hook with an original throat of 3.2 in reaches the ASME limit at 3.2 x 0.05 = 0.16 in of spread, which is under the 1/4 in cap, so 0.16 in governs.

Check yourself

1. Under ASME B30.10, a hook must be removed from service when the throat opening has increased by how much?

2. Under ASME B30.10, wear in the bowl or saddle of a hook requires removal from service when it exceeds what portion of the original section dimension?

Facts checked 2026-11-15 · Sources: OSHA 29 CFR 1926.251: Rigging equipment for material handling, OSHA 29 CFR 1910.184: Slings, NCCCO: Rigger Level I written exam outline

Rigger Level I (NCCCO) cheat sheet: every key fact on one page →