Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Safety0/5
    1. Worker rights, employer duties and reporting hazards
    2. The hierarchy of controls and personal protective equipment
    3. Lockout/tagout, machine guarding and electrical hazards
    4. Hazard communication, chemical storage and fire
    5. Confined spaces and ergonomics
  2. 2.Quality Practices & Inspection0/4
    1. Quality systems, audits and the internal customer
    2. Prevention versus detection: cost of quality and inspection points
    3. Control charts and variation
    4. Root cause tools, nonconforming product and corrective action
  3. 3.Measurement & Blueprint Reading0/5
    1. Choosing and reading micrometers and calipers
    2. Indicators, transfer gauges and go/no-go gauges
    3. Calibration and conditions that affect accuracy
    4. Reading the print: views, lines, scale and the title block
    5. Limits, tolerance, allowance and GD&T basics
  4. 4.Manufacturing Processes & Materials0/5
    1. How parts are shaped: casting, molding, forging, machining and additive
    2. Joining, heat treating and finishing
    3. Materials and their properties
    4. Volume, setup cost, takt time and the bottleneck
    5. Work orders, travelers, traceability and connected machines
  5. 5.Lean & Continuous Improvement0/5
    1. Value-added, non-value-added and necessary work
    2. The eight wastes
    3. 5S, visual management and the andon
    4. Standard work, kaizen and plan-do-check-act
    5. Pull, value stream maps, quick changeover and poka-yoke
  6. 6.Maintenance Awareness0/5
    1. Reactive, preventive and predictive maintenance, and TPM
    2. PM discipline, maintenance records and warning signs
    3. Lockout/tagout and stored energy
    4. Lubrication, bearings and shaft alignment
    5. Belts, chains, motor overloads and fluid power
Saved in this browser. Move it to another device →
← Safety

Chapter 1 · Lesson 4 of 5

Hazard communication, chemical storage and fire

1 min read

Under OSHA's hazard communication standard, safety data sheets must be readily accessible in the work area on every shift, with no need to ask a manager. Each sheet uses the same section order, so first aid, handling and storage, and required PPE are always in the same place.

Any workplace container, including a spray bottle filled from a labeled drum, must show the product identity and its hazards once it is left for others to use. The narrow exception is a portable container filled from a labeled container and intended only for the immediate use of the person who filled it.

  • Keep flammables and oxidizers in separate areas, because an oxidizer feeds a fire; the SDS handling and storage section lists incompatibilities.
  • On an energized electrical fire use a Class C rated agent such as carbon dioxide or dry chemical, never water; Class D is for combustible metals.
  • PASS means pull, aim at the base of the flames, squeeze and sweep, and only on a small fire with an exit behind you.
  • Solvent-soaked rags go in a labeled, closed container for that waste stream, never loose in an open bin or rinsed down a drain.

Check yourself

1. A fire starts inside an energized electrical control cabinet. Which extinguisher choice is correct?

2. A worker fills a spray bottle with solvent from a labeled drum and leaves the bottle at the workstation for other workers to use. What does hazard communication require?

Facts checked 2026-11-15 · Sources: MSSC: Certified Production Technician (CPT 4.0), OSHA 29 CFR 1910.147: The control of hazardous energy (lockout/tagout), OSHA: Hazard Communication

Production Technician cheat sheet: every key fact on one page →