Under OSHA's hazard communication standard, safety data sheets must be readily accessible in the work area on every shift, with no need to ask a manager. Each sheet uses the same section order, so first aid, handling and storage, and required PPE are always in the same place.
Any workplace container, including a spray bottle filled from a labeled drum, must show the product identity and its hazards once it is left for others to use. The narrow exception is a portable container filled from a labeled container and intended only for the immediate use of the person who filled it.
- Keep flammables and oxidizers in separate areas, because an oxidizer feeds a fire; the SDS handling and storage section lists incompatibilities.
- On an energized electrical fire use a Class C rated agent such as carbon dioxide or dry chemical, never water; Class D is for combustible metals.
- PASS means pull, aim at the base of the flames, squeeze and sweep, and only on a small fire with an exit behind you.
- Solvent-soaked rags go in a labeled, closed container for that waste stream, never loose in an open bin or rinsed down a drain.
Check yourself
1. A fire starts inside an energized electrical control cabinet. Which extinguisher choice is correct?
2. A worker fills a spray bottle with solvent from a labeled drum and leaves the bottle at the workstation for other workers to use. What does hazard communication require?