Chapters0/29 ▾
Chapter 6 · Lesson 5 of 5
Belts, chains, motor overloads and fluid power
1 min read
Belt tension is checked by deflection. A common rule is 1/64 inch of deflection per inch of span, under the force the drive maker specifies. Example: a 40-inch span gives 40 ÷ 64 = 5/8 inch.
A loose belt slips, overheats and glazes its sidewalls; an over-tight belt overloads the shafts and bearings. A roller chain that has stretched is really worn at each pin and bushing, so a worn chain is replaced along with its sprockets rather than patched with new links.
In a motor starter, fuses and breakers protect the wiring from short circuits and act very fast at very high current. The overload relay is sized to the motor and trips on a smaller, sustained overcurrent that would slowly cook the windings.
An overload that trips repeatedly is telling you something is wrong, such as a jam, a failing bearing, low voltage or a lost phase, so stop the motor and have the cause found.
In hydraulics, the pump creates flow; pressure rises only when that flow meets resistance. The relief valve caps maximum pressure and the directional valve routes flow. Milky oil that stays hazy after standing points to water, while foam that clears points to air. In pneumatics, water collects in the filter bowl and is drained on the PM schedule.
Check yourself
1. Which statement about a hydraulic system is correct?
2. A motor's overload relay has tripped three times during one shift. What should be done?
Facts checked 2026-11-15 · Sources: MSSC: Certified Production Technician (CPT 4.0), OSHA 29 CFR 1910.147: The control of hazardous energy (lockout/tagout)