Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Safety0/4
    1. Lockout, tagout and stored electrical energy
    2. Refrigerant, cylinders and pressure hazards
    3. Carbon monoxide and combustion hazards
    4. PPE, brazing and job-site hazards
  2. 2.Tools & Measurement0/5
    1. Measuring temperature and proving the thermometer
    2. Humidity, wet bulb and dew point
    3. Gauge pressure, absolute pressure and vacuum
    4. Using electrical meters correctly
    5. Airflow, leak detection and charging tools
  3. 3.Basic Electrical0/4
    1. Ohm's law, power and power factor
    2. Series, parallel and reading a ladder diagram
    3. Transformers, single-phase and three-phase power
    4. Single-phase motors, capacitors and winding tests
  4. 4.Science & Refrigeration Cycle0/4
    1. Heat, sensible and latent heat, and heat transfer
    2. Saturation and the four main components
    3. Calculating superheat and subcooling
    4. Metering devices and reading the charge
  5. 5.Construction, Comfort & Airflow0/4
    1. The building envelope: insulation, air sealing and windows
    2. Loads, equipment sizing and comfort
    3. Airflow, static pressure and capacity
    4. Duct leakage, noise, filters and ventilation
  6. 6.AC Components & Operation0/4
    1. Compressors and keeping liquid out
    2. Outdoor coil, indoor coil and condensate
    3. Metering devices, the TXV bulb and charging method
    4. Line sets, accessories, service valves and thermostats
  7. 7.AC Diagnosis & Service0/4
    1. Reading superheat and subcooling patterns
    2. Troubleshooting the control circuit
    3. Compressor electrical faults
    4. Airside, static pressure and condensate problems
Saved in this browser. Move it to another device →
← Tools & Measurement

Chapter 2 · Lesson 4 of 5

Using electrical meters correctly

1 min read

Each electrical measurement has its own connection. Voltage is a difference in potential between two points, so the leads go in parallel across the load while the circuit is live; with the disconnect open you simply read zero.

Resistance is measured with power off, because the ohmmeter supplies its own small current and outside voltage gives false readings and can damage the meter. Current is measured with a clamp around a single conductor.

SymptomCauseFix
Coil reads lower ohms than expectedParallel parts still wired inDisconnect one lead to isolate it
Clamp on a whole cord reads near zeroSupply and return fields cancelClamp one conductor or use a line splitter
Odd readings on an ECM or inverter unitWaveform is not a clean sine waveUse a true-RMS meter

An averaging meter assumes a sine wave, so it can be well off on the chopped waveforms of electronically commutated motors and variable-frequency drives. Also check the function setting: reading a 24-volt AC control circuit on the DC volts setting gives a meaningless number.