Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Safety0/4
    1. Lockout, tagout and stored electrical energy
    2. Refrigerant, cylinders and pressure hazards
    3. Carbon monoxide and combustion hazards
    4. PPE, brazing and job-site hazards
  2. 2.Tools & Measurement0/5
    1. Measuring temperature and proving the thermometer
    2. Humidity, wet bulb and dew point
    3. Gauge pressure, absolute pressure and vacuum
    4. Using electrical meters correctly
    5. Airflow, leak detection and charging tools
  3. 3.Basic Electrical0/4
    1. Ohm's law, power and power factor
    2. Series, parallel and reading a ladder diagram
    3. Transformers, single-phase and three-phase power
    4. Single-phase motors, capacitors and winding tests
  4. 4.Science & Refrigeration Cycle0/4
    1. Heat, sensible and latent heat, and heat transfer
    2. Saturation and the four main components
    3. Calculating superheat and subcooling
    4. Metering devices and reading the charge
  5. 5.Construction, Comfort & Airflow0/4
    1. The building envelope: insulation, air sealing and windows
    2. Loads, equipment sizing and comfort
    3. Airflow, static pressure and capacity
    4. Duct leakage, noise, filters and ventilation
  6. 6.AC Components & Operation0/4
    1. Compressors and keeping liquid out
    2. Outdoor coil, indoor coil and condensate
    3. Metering devices, the TXV bulb and charging method
    4. Line sets, accessories, service valves and thermostats
  7. 7.AC Diagnosis & Service0/4
    1. Reading superheat and subcooling patterns
    2. Troubleshooting the control circuit
    3. Compressor electrical faults
    4. Airside, static pressure and condensate problems
Saved in this browser. Move it to another device →
← Back

Study guide · Chapter 2 of 7

Tools & Measurement Study Guide — NATE HVAC

28 free practice questions

Every diagnosis starts with a reading, and a reading is only as good as the instrument and the way it was taken. NATE Core questions on tools and measurement ask what an instrument actually senses, how to connect it, and how to tell whether its number can be trusted. This chapter covers temperature, humidity, pressure and vacuum, electrical meters, and the tools for airflow, leaks and charging.

Key takeaways

  • An infrared thermometer reads the surface it sees, never the air, so air temperature needs a probe in the moving airstream.
  • Heating air without adding moisture lowers relative humidity but leaves the dew point unchanged.
  • Absolute pressure equals gauge pressure plus local atmospheric pressure.
  • Only a micron gauge and a decay test with the pump valved off prove a deep vacuum.
  • Voltage is read in parallel on a live circuit, resistance on a dead and isolated component, and current with a clamp around one conductor.

Lessons in this chapter

5 short lessons · 5 min read

  1. 1Measuring temperature and proving the thermometer1 min
  2. 2Humidity, wet bulb and dew point1 min
  3. 3Gauge pressure, absolute pressure and vacuum1 min
  4. 4Using electrical meters correctly1 min
  5. 5Airflow, leak detection and charging tools1 min
View all questions & answers →

Facts checked 2026-11-15 · Sources: NATE: Certification exams

NATE HVAC cheat sheet: every key fact on one page →Next chapter: Basic Electrical →

Practice questions based on the published NATE knowledge areas and standard HVACR theory and service practice. NATE is a mark of North American Technician Excellence; this site is not affiliated with or endorsed by NATE. NATE certification is not a licence — HVAC licensing is set by your state and locality. Confirm current exam requirements with NATE and current code requirements with the authority having jurisdiction. About NATE certification →