Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Safety0/4
    1. Lockout, tagout and stored electrical energy
    2. Refrigerant, cylinders and pressure hazards
    3. Carbon monoxide and combustion hazards
    4. PPE, brazing and job-site hazards
  2. 2.Tools & Measurement0/5
    1. Measuring temperature and proving the thermometer
    2. Humidity, wet bulb and dew point
    3. Gauge pressure, absolute pressure and vacuum
    4. Using electrical meters correctly
    5. Airflow, leak detection and charging tools
  3. 3.Basic Electrical0/4
    1. Ohm's law, power and power factor
    2. Series, parallel and reading a ladder diagram
    3. Transformers, single-phase and three-phase power
    4. Single-phase motors, capacitors and winding tests
  4. 4.Science & Refrigeration Cycle0/4
    1. Heat, sensible and latent heat, and heat transfer
    2. Saturation and the four main components
    3. Calculating superheat and subcooling
    4. Metering devices and reading the charge
  5. 5.Construction, Comfort & Airflow0/4
    1. The building envelope: insulation, air sealing and windows
    2. Loads, equipment sizing and comfort
    3. Airflow, static pressure and capacity
    4. Duct leakage, noise, filters and ventilation
  6. 6.AC Components & Operation0/4
    1. Compressors and keeping liquid out
    2. Outdoor coil, indoor coil and condensate
    3. Metering devices, the TXV bulb and charging method
    4. Line sets, accessories, service valves and thermostats
  7. 7.AC Diagnosis & Service0/4
    1. Reading superheat and subcooling patterns
    2. Troubleshooting the control circuit
    3. Compressor electrical faults
    4. Airside, static pressure and condensate problems
Saved in this browser. Move it to another device →
← Construction, Comfort & Airflow

Chapter 5 · Lesson 2 of 4

Loads, equipment sizing and comfort

1 min read

A proper load calculation, such as ACCA Manual J, adds up each room's real gains and losses: walls and ceilings, glass area with its orientation and shading, infiltration, and internal gains from people, lights and equipment.

Two rooms of the same size can need very different airflow. Infiltrating outdoor air adds both sensible load, because it must be cooled, and latent load, because it must be dried.

Replacement equipment is sized from a load calculation of the house as it exists now. If the house has new windows and insulation, copying the old nameplate usually oversizes the new unit. An oversized system satisfies the thermostat in short bursts, and the coil never stays cold and wet long enough to remove moisture, so the space feels clammy.

  • Comfort depends on air temperature, humidity, air movement and mean radiant temperature, the average temperature of surrounding surfaces.
  • A person beside a cold window feels cold even when the air is fine, because the body radiates heat to the glass.
  • High humidity slows sweat evaporation, so the same dry-bulb temperature feels warmer.

Example: in humid summer weather a house holds temperature but feels damp, the system runs in short bursts, and charge, airflow and the coil all check out. Lowering the setpoint will not help. The likely cause is oversized equipment, and the lasting fix comes from a load calculation.

Check yourself

1. In humid summer weather a house holds temperature easily but feels damp and clammy; the system satisfies the thermostat in short bursts, and measured airflow, charge, and coil condition are all normal. What is the most likely cause?

2. Two bedrooms in the same house have identical floor area, but one faces west with a large window and is used as an office by two people with computer equipment. How does a proper load calculation treat them?