Chapters0/29 ▾
Chapter 5 · Lesson 1 of 4
The building envelope: insulation, air sealing and windows
1 min read
Fibrous insulation works by trapping air in small pockets, which slows conduction and stops convection loops inside the cavity. Compressed or gapped insulation loses much of its value. Insulation does not stop air movement, though, because fibers are air-permeable. Leaks at an attic hatch, top plates or recessed lights need air sealing, a separate job from insulating.
- Water vapor condenses where it meets a surface below its dew point. In a heating climate the vapor retarder goes on the warm-in-winter side; retarders on both faces trap moisture.
- Solar heat gain coefficient (SHGC) is the share of sunlight a window lets in; lower SHGC cuts sun-driven cooling load. U-factor describes conducted heat, not solar gain.
- Never cut, notch or bore an engineered truss member; any change to a truss is the truss designer's or engineer's call, not the installer's. Reroute or resize the duct instead.
- Clear span on a plan is the open distance between supports, which tells you where trunks and equipment can go.
Example: a homeowner with hot afternoons in a west-facing room asks for new windows. The property to look at is a lower SHGC, not a higher U-factor or more visible light.
Check yourself
1. An attic is fully insulated, yet the owner reports cold drafts and high winter heating bills; the attic hatch, wall top plates, and recessed-light penetrations are all open to the attic. What should the technician explain?
2. Why does a fibrous batt or blanket insulation slow heat flow through a wall or attic assembly?
Facts checked 2026-11-15 · Sources: NATE: Certification exams, ACCA Manual J: Residential Load Calculation
NATE HVAC cheat sheet: every key fact on one page →