Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Safety0/4
    1. Lockout, tagout and stored electrical energy
    2. Refrigerant, cylinders and pressure hazards
    3. Carbon monoxide and combustion hazards
    4. PPE, brazing and job-site hazards
  2. 2.Tools & Measurement0/5
    1. Measuring temperature and proving the thermometer
    2. Humidity, wet bulb and dew point
    3. Gauge pressure, absolute pressure and vacuum
    4. Using electrical meters correctly
    5. Airflow, leak detection and charging tools
  3. 3.Basic Electrical0/4
    1. Ohm's law, power and power factor
    2. Series, parallel and reading a ladder diagram
    3. Transformers, single-phase and three-phase power
    4. Single-phase motors, capacitors and winding tests
  4. 4.Science & Refrigeration Cycle0/4
    1. Heat, sensible and latent heat, and heat transfer
    2. Saturation and the four main components
    3. Calculating superheat and subcooling
    4. Metering devices and reading the charge
  5. 5.Construction, Comfort & Airflow0/4
    1. The building envelope: insulation, air sealing and windows
    2. Loads, equipment sizing and comfort
    3. Airflow, static pressure and capacity
    4. Duct leakage, noise, filters and ventilation
  6. 6.AC Components & Operation0/4
    1. Compressors and keeping liquid out
    2. Outdoor coil, indoor coil and condensate
    3. Metering devices, the TXV bulb and charging method
    4. Line sets, accessories, service valves and thermostats
  7. 7.AC Diagnosis & Service0/4
    1. Reading superheat and subcooling patterns
    2. Troubleshooting the control circuit
    3. Compressor electrical faults
    4. Airside, static pressure and condensate problems
Saved in this browser. Move it to another device →
← Tools & Measurement

Chapter 2 · Lesson 3 of 5

Gauge pressure, absolute pressure and vacuum

1 min read

A service gauge is set so that the surrounding atmosphere reads zero. It measures the difference between system pressure and the atmosphere, in psig. Absolute pressure, in psia, counts up from a perfect vacuum, so it equals the gauge reading plus local atmospheric pressure.

Example: at sea level, where the atmosphere is about 14.7 psi, a gauge reading of 60 psig is about 74.7 psia. Gas-law calculations and deep-vacuum work are done in absolute terms.

The vacuum part of a compound gauge is squeezed into a small arc, so it cannot tell a rough vacuum from a deep one. A micron gauge measures absolute pressure in the very low range where moisture and air actually matter.

Connect it away from the pump so it reads the system, not the pump. Then valve off the pump and watch: a reading that rises and levels off points to moisture still boiling off, while a reading that keeps climbing means a leak.

Check yourself

1. What actually demonstrates that an evacuated system has reached and is holding an acceptable vacuum?

2. A pressure gauge connected to a system that is open to the atmosphere reads zero. What does that tell you about the pressure inside the system?

Facts checked 2026-11-15 · Sources: NATE: Certification exams