Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Safety0/4
    1. Lockout, tagout and stored electrical energy
    2. Refrigerant, cylinders and pressure hazards
    3. Carbon monoxide and combustion hazards
    4. PPE, brazing and job-site hazards
  2. 2.Tools & Measurement0/5
    1. Measuring temperature and proving the thermometer
    2. Humidity, wet bulb and dew point
    3. Gauge pressure, absolute pressure and vacuum
    4. Using electrical meters correctly
    5. Airflow, leak detection and charging tools
  3. 3.Basic Electrical0/4
    1. Ohm's law, power and power factor
    2. Series, parallel and reading a ladder diagram
    3. Transformers, single-phase and three-phase power
    4. Single-phase motors, capacitors and winding tests
  4. 4.Science & Refrigeration Cycle0/4
    1. Heat, sensible and latent heat, and heat transfer
    2. Saturation and the four main components
    3. Calculating superheat and subcooling
    4. Metering devices and reading the charge
  5. 5.Construction, Comfort & Airflow0/4
    1. The building envelope: insulation, air sealing and windows
    2. Loads, equipment sizing and comfort
    3. Airflow, static pressure and capacity
    4. Duct leakage, noise, filters and ventilation
  6. 6.AC Components & Operation0/4
    1. Compressors and keeping liquid out
    2. Outdoor coil, indoor coil and condensate
    3. Metering devices, the TXV bulb and charging method
    4. Line sets, accessories, service valves and thermostats
  7. 7.AC Diagnosis & Service0/4
    1. Reading superheat and subcooling patterns
    2. Troubleshooting the control circuit
    3. Compressor electrical faults
    4. Airside, static pressure and condensate problems
Saved in this browser. Move it to another device →
← Basic Electrical

Chapter 3 · Lesson 1 of 4

Ohm's law, power and power factor

1 min read

Two formulas handle most NATE electrical math. Ohm's law, E = I × R, links voltage, current and resistance. The power formula, P = E × I, links watts to volts and amps.

Rearrange either one to find the value you need: R = E ÷ I, I = P ÷ E, and so on. When you work out resistance from live readings, you use the formula; you never put an ohmmeter on an energized circuit.

Known readingsFormulaResult
240 V across a heater, 12 A through itR = E ÷ I20 ohms
3,600 W element at 240 VI = P ÷ E15 amps
Transformer rated 75 VA, 24 V secondaryI = VA ÷ VAbout 3.1 amps

Volts times amps equals watts only for a purely resistive load such as a heat strip, where the power factor is one. In an inductive load such as a motor, transformer or solenoid coil, current lags voltage, so true power in watts is less than the volt-amps you get by multiplying the meter readings.

Power factor is watts divided by volt-amps. Capacitance makes current lead, which is why it can offset a motor's lagging power factor.

Check yourself

1. A technician needs to know the current draw of a 4,800 watt electric heat element that operates at 240 volts, in order to compare it with a clamp-on reading. What current should the element draw?

2. A technician clamps 8 amps on a motor running at 240 volts, but a power meter connected to the same motor reports fewer watts than 240 multiplied by 8. What is the explanation?

Facts checked 2026-11-15 · Sources: NATE: Certification exams

NATE HVAC cheat sheet: every key fact on one page →