Chapters0/35 ▾
Chapter 5 · Lesson 4 of 5
The lens clock and other dispensing instruments
Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.
1 min read
A lens clock measures the curve of one surface, using two fixed outer pins and a moving center pin. On a spherical surface it reads the same in every direction at one spot. Two different readings 90 degrees apart mean the surface is toric, and the difference is the surface cylinder.
The dial assumes an index of 1.530, so on another material multiply by (n − 1)/0.530. Example: +5.00 on a CR-39 lens of index 1.50 is 5.00 × 0.50/0.53, about +4.72 D. On polycarbonate, index 1.586, a −6.00 reading becomes −6.00 × 0.586/0.53, about −6.63 D.
Adding the front and back readings gives only an approximate, nominal power. It ignores center thickness, so the lensmeter is still needed for the verified back vertex power.
Measuring tools for contact lens work, such as the radiuscope and keratometer, measure a lens or corneal radius and are not used to find a spectacle base curve.
| Instrument | What it measures |
|---|---|
| Corneal reflex pupillometer | Monocular PDs from the corneal light reflex, unaffected by an irregular pupil |
| Distometer | Distance from the corneal apex to the back surface of the lens |
| Circumference gauge | Perimeter of a lens, pattern or eyewire groove |
| Thickness caliper | Center or edge thickness of the finished lens |
Check yourself
1. At final inspection an optician must confirm the base curve actually put on a lens, the perimeter of the lens against the eyewire groove, and the wearer's vertex distance. Which instruments do those three jobs, in that order?
2. A lens clock is set on the front surface of a lens and rotated through a full sweep at the same spot. The reading changes from +6.00 at one position to +8.00 ninety degrees away. What does this show about that surface?
Facts checked 2026-11-15 · Sources: American Board of Opticianry and National Contact Lens Examiners (ABO-NCLE), 20/20 Magazine: Honing spectacle lens verification expertise (ANSI Z80.1 sphere tolerances, compensated powers), The Vision Council: Lens Marking Guidelines (34 mm engravings, prism reference point), 20/20 Magazine: Diopter 1.53, the lens measure convention
Optician (ABO) cheat sheet: every key fact on one page →