Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/35 ▾
  1. 1.Ophthalmic Optics0/5
    1. Refractive index and lens power
    2. Surface power and the lens measure
    3. Prism and Prentice's rule
    4. Cylinder power in any meridian
    5. Aberrations, Abbe value and vertex distance
  2. 2.Lens Products & Materials0/5
    1. Choosing a lens material
    2. Coatings, tints and light control
    3. Bifocal and trifocal segments
    4. Progressive lenses
    5. High-power designs and impact testing
  3. 3.Prescription Analysis & Math0/5
    1. Reading and transposing a prescription
    2. Meridian powers and spherical equivalent
    3. Near and intermediate powers from the add
    4. Prism, vertical imbalance and slab-off
    5. Decentration, blank size, vertex and tilt
  4. 4.Frames, Measuring & Fitting0/5
    1. Frame materials and how they behave
    2. Temples, bridges and pads
    3. The boxing system, decentration and blank size
    4. Measuring for multifocals and progressives
    5. Pantoscopic tilt and bench alignment
  5. 5.Instruments & Verification0/5
    1. Setting up and reading a lensmeter
    2. Verifying multifocals and progressives
    3. Verifying prism and centration
    4. The lens clock and other dispensing instruments
    5. Tolerances and final inspection
  6. 6.Laws, Standards & Practice0/5
    1. The FDA impact-resistance rule
    2. The FTC Eyeglass Rule
    3. The FTC Contact Lens Rule
    4. ANSI standards and safety eyewear
    5. Scope of practice, privacy and referral
  7. 7.Ocular Anatomy & Pathology0/5
    1. The front of the eye: cornea, aqueous humor and tear drainage
    2. The crystalline lens: accommodation, aphakia and pseudophakia
    3. The retina, the optic nerve and the visual pathway
    4. Eye diseases an optician must recognize and refer
    5. Visual acuity, astigmatism types and binocular vision
Saved in this browser. Move it to another device →
← Instruments & Verification

Chapter 5 · Lesson 4 of 5

The lens clock and other dispensing instruments

Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.

1 min read

A lens clock measures the curve of one surface, using two fixed outer pins and a moving center pin. On a spherical surface it reads the same in every direction at one spot. Two different readings 90 degrees apart mean the surface is toric, and the difference is the surface cylinder.

The dial assumes an index of 1.530, so on another material multiply by (n − 1)/0.530. Example: +5.00 on a CR-39 lens of index 1.50 is 5.00 × 0.50/0.53, about +4.72 D. On polycarbonate, index 1.586, a −6.00 reading becomes −6.00 × 0.586/0.53, about −6.63 D.

Adding the front and back readings gives only an approximate, nominal power. It ignores center thickness, so the lensmeter is still needed for the verified back vertex power.

Measuring tools for contact lens work, such as the radiuscope and keratometer, measure a lens or corneal radius and are not used to find a spectacle base curve.

InstrumentWhat it measures
Corneal reflex pupillometerMonocular PDs from the corneal light reflex, unaffected by an irregular pupil
DistometerDistance from the corneal apex to the back surface of the lens
Circumference gaugePerimeter of a lens, pattern or eyewire groove
Thickness caliperCenter or edge thickness of the finished lens

Check yourself

1. At final inspection an optician must confirm the base curve actually put on a lens, the perimeter of the lens against the eyewire groove, and the wearer's vertex distance. Which instruments do those three jobs, in that order?

2. A lens clock is set on the front surface of a lens and rotated through a full sweep at the same spot. The reading changes from +6.00 at one position to +8.00 ninety degrees away. What does this show about that surface?

Facts checked 2026-11-15 · Sources: American Board of Opticianry and National Contact Lens Examiners (ABO-NCLE), 20/20 Magazine: Honing spectacle lens verification expertise (ANSI Z80.1 sphere tolerances, compensated powers), The Vision Council: Lens Marking Guidelines (34 mm engravings, prism reference point), 20/20 Magazine: Diopter 1.53, the lens measure convention

Optician (ABO) cheat sheet: every key fact on one page →