Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/35 ▾
  1. 1.Ophthalmic Optics0/5
    1. Refractive index and lens power
    2. Surface power and the lens measure
    3. Prism and Prentice's rule
    4. Cylinder power in any meridian
    5. Aberrations, Abbe value and vertex distance
  2. 2.Lens Products & Materials0/5
    1. Choosing a lens material
    2. Coatings, tints and light control
    3. Bifocal and trifocal segments
    4. Progressive lenses
    5. High-power designs and impact testing
  3. 3.Prescription Analysis & Math0/5
    1. Reading and transposing a prescription
    2. Meridian powers and spherical equivalent
    3. Near and intermediate powers from the add
    4. Prism, vertical imbalance and slab-off
    5. Decentration, blank size, vertex and tilt
  4. 4.Frames, Measuring & Fitting0/5
    1. Frame materials and how they behave
    2. Temples, bridges and pads
    3. The boxing system, decentration and blank size
    4. Measuring for multifocals and progressives
    5. Pantoscopic tilt and bench alignment
  5. 5.Instruments & Verification0/5
    1. Setting up and reading a lensmeter
    2. Verifying multifocals and progressives
    3. Verifying prism and centration
    4. The lens clock and other dispensing instruments
    5. Tolerances and final inspection
  6. 6.Laws, Standards & Practice0/5
    1. The FDA impact-resistance rule
    2. The FTC Eyeglass Rule
    3. The FTC Contact Lens Rule
    4. ANSI standards and safety eyewear
    5. Scope of practice, privacy and referral
  7. 7.Ocular Anatomy & Pathology0/5
    1. The front of the eye: cornea, aqueous humor and tear drainage
    2. The crystalline lens: accommodation, aphakia and pseudophakia
    3. The retina, the optic nerve and the visual pathway
    4. Eye diseases an optician must recognize and refer
    5. Visual acuity, astigmatism types and binocular vision
Saved in this browser. Move it to another device →
← Prescription Analysis & Math

Chapter 3 · Lesson 3 of 5

Near and intermediate powers from the add

Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.

1 min read

The add is the extra plus a presbyope needs for close work, and it is always added algebraically to the sphere. The cylinder power and axis never change, because the astigmatism is the same at every distance. A single-vision reading pair is the distance sphere plus the full add.

For a computer or other intermediate pair, the usual approach is half the add. The full add would place the clear range too close for a screen at arm's length.

Example: OD −2.50 −0.75 × 180 with an add of +2.00. The reading lens is −2.50 + 2.00 = −0.50, so −0.50 −0.75 × 180. The intermediate lens uses +1.00: −2.50 + 1.00 = −1.50, so −1.50 −0.75 × 180. Notice that adding plus to a minus sphere makes it less minus.

For a bifocal or progressive, the same add is written once and the laboratory builds it into the segment or near zone. Plus spheres follow the same rule: +1.25 −0.50 × 070 with a +2.00 add gives an intermediate lens of +1.25 + 1.00 = +2.25, written +2.25 −0.50 × 070, and a reading lens of +3.25 −0.50 × 070.

Check yourself

1. A wearer's distance prescription for the right eye is -3.75 -1.00 x 095 with an Add of +2.50. What single-vision near prescription should be ordered for that eye?

2. A wearer's left distance prescription is +1.25 -0.50 x 070 with an Add of +2.00. If a single-vision pair is ordered for computer use at half the Add power, what should the left lens be?

Facts checked 2026-11-15 · Sources: American Board of Opticianry and National Contact Lens Examiners (ABO-NCLE)

Optician (ABO) cheat sheet: every key fact on one page →