Optician (ABO) Cheat Sheet: Key Facts
Varies by state. Your state sets this exam: the number of questions, time limit, pass mark and any state-law section can differ from this practice. Check your state's official handbook or licensing board before you test.
Every key takeaway and common trap from the Optician (ABO) study guide on one page, grouped by chapter. Tap a lesson link to read the full explanation.
54 facts · 7 chaptersFacts checked 2026-11-16
Chapter 1
Ophthalmic Optics
Key takeaways
- Lens power in diopters is the reciprocal of the focal length in meters, so a 25 cm focal length is 4.00 D, never 25 D. → Refractive index and lens power
- Surface power is (n − 1)/r, and a lens clock calibrated for 1.53 must be corrected by (n − 1)/0.53 on any other material. → Surface power and the lens measure
- Prentice's rule gives prism as power times decentration in centimeters, with the base toward the optical center in plus lenses and away from it in minus lenses. → Prism and Prentice's rule
- In an oblique meridian the cylinder acts by sin² of the angle from the axis: 25, 50 and 75 percent at 30, 45 and 60 degrees. → Cylinder power in any meridian
- A plus lens moved closer to the eye loses effective power and needs more plus, which the formula F/(1 − dF) confirms. → Aberrations, Abbe value and vertex distance
Common trap
- Wrong answers often skip the unit change. A 25 cm focal length shows up as +25.00 D or +2.50 D, but 1/0.25 m is +4.00 D. Convert centimeters to meters before taking the reciprocal. → Refractive index and lens power
- Two distractors appear again and again: millimeters left unconverted (3 mm × 4.00 = 12) and perpendicular prisms simply added (5 + 12 = 17). Use centimeters, and use the hypotenuse. → Prism and Prentice's rule
- Vertex questions hide a direction error. Moving any lens farther from the eye makes it act more plus, so a plus lens moved away needs less plus, and a minus lens moved closer needs less minus. If your answer goes the other way, recheck the sign of d. → Aberrations, Abbe value and vertex distance
Quick reference
| Angle from the axis | Share of cylinder in effect |
|---|---|
| 0 degrees (on the axis) | None |
| 30 degrees | 25 percent |
| 45 degrees | 50 percent |
| 60 degrees | 75 percent |
| 90 degrees | All of it |
Chapter 2
Lens Products & Materials
Key takeaways
- Children, sports wearers, monocular patients and drilled rimless mountings call for polycarbonate or Trivex, because impact safety ranks ahead of thinness. → Choosing a lens material
- Index controls thickness, specific gravity controls weight, and Abbe value controls color fringing; judge each property separately. → Choosing a lens material
- A dark tint does not block ultraviolet, so an untreated CR-39 sun lens needs a separate UV treatment. → Coatings, tints and light control
- Image jump equals the add times the distance from the segment top to the segment's optical center, which is why an Executive style has essentially none. → Bifocal and trifocal segments
- Progressive lenses need monocular PDs and a fitting height taken in the adjusted frame, plus a frame deep enough for the design's minimum fitting height. → Progressive lenses
Common trap
- Switching CR-39 to Trivex barely thins a lens, since 1.53 is close to 1.50; Trivex is chosen for low weight and impact strength. And for a thick −9.00 lens, a smaller frame centered on the PD comes before any material change. → Choosing a lens material
- A photochromic that will not darken in the car is not defective; the windshield has removed the UV that drives it. Answers that blame heat get it backward, because warmth makes photochromics lighter, not darker. → Coatings, tints and light control
- Safety-lens questions mix up the categories. The 3.0 mm minimum belongs to the basic-impact category, while high-impact prescription safety lenses may be as thin as 2.0 mm. The 5/8-inch, 50-inch drop is the federal dress-lens test, not the occupational one; the 1-inch ball belongs to the ANSI basic-impact test, and the fast 1/4-inch ball to the high-impact test. → High-power designs and impact testing
Quick reference
| Material | Index | What it is known for |
|---|---|---|
| CR-39 | About 1.50 | Good optics, but not high impact and brittle at a drill hole |
| Trivex | 1.53 | Lightest standard material (specific gravity about 1.11) and high impact |
| Polycarbonate | 1.586 | High impact, specific gravity about 1.20, inherent UV blocking |
| High index | 1.67 to 1.74 | Thinnest edges, but lower Abbe value and more surface reflection |
| Test | What it involves |
|---|---|
| FDA dress-lens drop ball (21 CFR 801.410) | A 5/8-inch steel ball of about 0.56 ounce dropped 50 inches onto the upper surface; the lens must not fracture |
| ANSI Z87.1 high-impact safety lens | At least 2.0 mm thick, a high-velocity 1/4-inch ball test, and the maker's mark followed by a plus sign |
Chapter 3
Prescription Analysis & Math
Key takeaways
- To transpose, add the sphere and cylinder, flip the cylinder sign, and turn the axis 90 degrees so it stays between 001 and 180. → Meridian powers and spherical equivalent
- The sphere acts along the axis meridian and the full cylinder acts 90 degrees away; the spherical equivalent is the sphere plus half the cylinder. → Meridian powers and spherical equivalent
- The add is added to the sphere only, and an intermediate single-vision lens usually uses half of it. → Near and intermediate powers from the add
- Vertical prisms with opposite bases add between the eyes, while the same base in both eyes subtracts. → Prism, vertical imbalance and slab-off
- Minimum blank size is the effective diameter plus twice the per-lens decentration plus about 2 mm for edging. → Decentration, blank size, vertex and tilt
Common trap
- A favorite wrong answer flips the cylinder sign and the axis but keeps the old sphere. Another adds 90 to an axis already over 90, giving an impossible value like 200. Do all three steps, every time. → Reading and transposing a prescription
- The classic sign error subtracts the add from a minus sphere, turning −2.50 into −4.50 instead of −0.50. Another wrong choice adds the add to the cylinder. Only the sphere moves, and it always moves in the plus direction. → Near and intermediate powers from the add
Quick reference
| Two meridian powers | Type of astigmatism |
|---|---|
| Both minus | Compound myopic |
| Both plus | Compound hyperopic |
| One plus, one minus | Mixed |
| One plano, one minus or plus | Simple myopic or simple hyperopic |
Chapter 4
Frames, Measuring & Fitting
Key takeaways
- Acetate is thermoplastic and must be held in its new shape until cool, while epoxy returns toward its molded shape when reheated. → Frame materials and how they behave
- A rash at the pads and end pieces of a Monel frame points to nickel allergy, and the fix is a titanium or stainless steel frame. → Frame materials and how they behave
- In the boxing system, frame PD is A plus DBL, and decentration per lens is half the frame PD minus that eye's monocular PD. → The boxing system, decentration and blank size
- Segment inset per lens is half the difference between the distance and near PDs, and all heights are measured from the lowest point of the lens. → Measuring for multifocals and progressives
- Lower the optical center about 1 mm for every 2 degrees of pantoscopic tilt, and check temple parallelism with the frame upside down. → Pantoscopic tilt and bench alignment
Common trap
- Answers that only change the pads miss the end pieces, which also touch the skin, and replating merely delays nickel release. For an allergy, change the frame material. → Frame materials and how they behave
- Averaging two unequal monocular PDs puts both centers in the wrong place, and adding the decentration only once undersizes the blank. Decentration counts twice in the blank-size formula. → The boxing system, decentration and blank size
- Checking temple parallelism with the frame standing on its temple tips is the common error, because tip curl and tip angle hide the fault. Turn the frame upside down so it rests on the top of the front and the tops of the open temples. → Pantoscopic tilt and bench alignment
Chapter 5
Instruments & Verification
Key takeaways
- Focus the lensmeter eyepiece for each operator, and read single-vision lenses with the concave side against the stop to get back vertex power. → Setting up and reading a lensmeter
- The cylinder is the difference between the two focus readings, not the second reading itself. → Setting up and reading a lensmeter
- Front-surface multifocal adds are read as front vertex power, and progressive prism is read at the prism reference point. → Verifying multifocals and progressives
- Prism is read as target displacement with the lens held where it will sit when worn; sliding the lens to center the target erases it. → Verifying prism and centration
- Final inspection starts with power and axis and ends with cosmetics and frame alignment. → Tolerances and final inspection
Common trap
- The most common wrong answer records the second drum reading as the cylinder, writing −2.00 instead of −1.25 in the example above. The cylinder is always the difference between the two readings. → Setting up and reading a lensmeter
- With an auxiliary prism, the two amounts add; they do not subtract. If a 4 prism diopter auxiliary prism brings the target back and 1 ring still shows in the original direction, the lens carries 5, not 3. → Verifying prism and centration
- An axis that is off by only a few degrees can still fail. If the table in the stem allows 2 degrees for cylinders above 1.50 D, a 1.75 D cylinder that is 3 degrees off is rejected, even though 3 degrees would pass on a weak cylinder. → Tolerances and final inspection
Quick reference
| Instrument | What it measures |
|---|---|
| Corneal reflex pupillometer | Monocular PDs from the corneal light reflex, unaffected by an irregular pupil |
| Distometer | Distance from the corneal apex to the back surface of the lens |
| Circumference gauge | Perimeter of a lens, pattern or eyewire groove |
| Thickness caliper | Center or edge thickness of the finished lens |
Chapter 6
Laws, Standards & Practice
Key takeaways
- Every eyeglass and sunglass lens, prescription or not, must be impact resistant unless a physician or optometrist directs otherwise in writing. → The FDA impact-resistance rule
- The FTC Eyeglass Rule requires an automatic, free copy of the prescription right after the refractive exam, with no purchase condition and no waiver. → The FTC Eyeglass Rule
- A contact lens prescription comes only from a completed fitting, generally lasts at least one year, and cannot be filled with a substitute brand. → The FTC Contact Lens Rule
- ANSI Z80.1 is a voluntary consensus standard that sets how a finished pair is judged, while Z87.1 governs occupational safety eyewear. → ANSI standards and safety eyewear
- Opticians fit and dispense; anything medical, ambiguous or outside scope goes back to the prescriber or out as a referral. → Scope of practice, privacy and referral
Common trap
- The one-year minimum expiration belongs to the Contact Lens Rule, not the Eyeglass Rule. Answers that give spectacle prescriptions a federal expiration are borrowing the wrong rule. → The FTC Eyeglass Rule
- Privacy distractors offer shortcuts: release it if the caller knows her date of birth, or read out only the powers. Knowing personal details proves nothing about consent, and a partial disclosure is still a disclosure. → Scope of practice, privacy and referral
Quick reference
| Profession | Core role |
|---|---|
| Ophthalmologist | Physician and surgeon; medical and surgical eye care |
| Optometrist | Examines, refracts and prescribes within state law |
| Optician | Fits and dispenses from a valid prescription |
Chapter 7
Ocular Anatomy & Pathology
Key takeaways
- The cornea supplies about 43 D, roughly two-thirds of the eye's power, while the crystalline lens is the part that changes power for near. → The front of the eye: cornea, aqueous humor and tear drainage
- Aqueous humor is made by the ciliary body and leaves through the trabecular meshwork into Schlemm's canal; tears leave through the puncta, canaliculi, lacrimal sac and nasolacrimal duct. → The front of the eye: cornea, aqueous humor and tear drainage
- For near focus the ciliary muscle contracts, the zonules slacken and the lens rounds up; aphakia needs strong plus, while pseudophakia means an implanted lens. → The crystalline lens: accommodation, aphakia and pseudophakia
- Macular degeneration takes central vision, open-angle glaucoma slowly takes side vision, and sudden pain with halos or new flashes with a curtain need emergency care right away. → Eye diseases an optician must recognize and refer
- A phoria is a hidden deviation that the alternate cover test reveals, and a prism moves the image the wearer sees toward its apex. → Visual acuity, astigmatism types and binocular vision
Common trap
- Exam options mix the two drainage systems. The puncta and nasolacrimal duct carry tears, never aqueous humor, and the tear route always runs puncta, canaliculi, sac, duct in that order. → The front of the eye: cornea, aqueous humor and tear drainage
- Many students assume a contracting muscle pulls the lens tighter. In accommodation the ciliary muscle contracts but the zonules slacken, and that slack is what lets the lens round up for near. → The crystalline lens: accommodation, aphakia and pseudophakia
- The fovea and macula are the places of best vision, so they are never the blind spot. The blind spot is the optic disc, and the fibers that cross at the chiasm are nasal, not temporal. → The retina, the optic nerve and the visual pathway
Quick reference
| Condition | What the customer notices | Urgency |
|---|---|---|
| Age-related macular degeneration | Blurry or wavy central vision; side vision kept | Eye doctor care; low-vision aids help |
| Open-angle glaucoma | Often nothing early; slow, painless loss of side vision | Regular exams with visual field testing |
| Acute angle-closure glaucoma | Sudden severe pain, halos around lights, red eye, nausea | Emergency, right away |
| Retinal detachment | Sudden new floaters, flashes, a dark curtain or shadow | Emergency, right away |