Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/32 ▾
  1. 1.Electrical Maintenance & Repair0/4
    1. Overloads, short circuits and ground faults
    2. Wiring receptacles, switches and fixtures
    3. Working safely: de-energize, test, then touch
    4. Ohm's law, Watt's law and the multimeter
  2. 2.Plumbing Maintenance & Repair0/4
    1. Supply, distribution and drainage: traps and vents
    2. Shutoffs, leaks and water damage
    3. Toilets, faucets and clearing drains
    4. Water heaters and joining pipe
  3. 3.HVAC Service & When to Refer0/5
    1. Airflow: filters, returns, registers and coils
    2. Condensate drains, pans and float switches
    3. Thermostats and controls
    4. The refrigeration cycle, superheat and EPA Section 608
    5. Furnaces, heat pumps, boilers and gas safety
  4. 4.Appliances, Locks & Keys0/5
    1. Refrigerators: moving heat out of the box
    2. Kitchen appliances: ranges, dishwashers, disposals and hoods
    3. Washers and dryers
    4. Reading schematics and testing parts
    5. Locks, keys and lockouts
  5. 5.Interior & Exterior Repair0/5
    1. Drywall repair
    2. Primer, paint and sheen
    3. Texture and caulk
    4. Doors, windows, cabinets and floors
    5. Exterior, ladders and suspect materials
  6. 6.Compliance, Safety & Fair Housing0/4
    1. Chemicals, PPE and sharps
    2. Lockout/tagout, confined spaces and ladders
    3. Fair housing in maintenance work
    4. Lead, asbestos, mold, pests and records
  7. 7.Facilities Operations & Professionalism0/5
    1. Prioritizing service requests and entering homes
    2. Make-ready turns, inspections and curb appeal
    3. Preventive maintenance, repair or replace, and contractors
    4. Pool and spa chemistry and math
    5. Life safety, reporting and records
Saved in this browser. Move it to another device →
← HVAC Service & When to Refer

Chapter 3 · Lesson 4 of 5

The refrigeration cycle, superheat and EPA Section 608

1 min read

Refrigerant travels through the compressor, the condenser, the metering device and the evaporator. The compressor discharges hot, high-pressure vapor. The condenser outdoors rejects that heat and turns it into a high-pressure liquid, which travels in the liquid line to the metering device.

After the metering device the pressure drops, and the evaporator boils the low-pressure liquid into the low-pressure vapor that returns to the compressor.

Superheat is how far the suction vapor has warmed above the temperature at which the refrigerant boiled. Subcooling is how far the liquid leaving the condenser has cooled below the temperature at which it condensed.

Example: a contractor reads a 38°F boiling temperature and a 49°F suction line, so superheat is 49 − 38 = 11°F. A 105°F condensing temperature and a 96°F liquid line give 105 − 96 = 9°F of subcooling.

  • EPA counts anyone who attaches gauges to measure pressure as a technician, so an uncertified technician does not connect them.
  • Refrigerant in scrapped window units must be recovered before disposal; venting is prohibited indoors or out.
  • An old thermostat with a mercury bulb is kept intact and sent for universal waste recycling.

Check yourself