CAMT Apartment Maintenance Cheat Sheet: Key Facts
Every key takeaway and common trap from the CAMT Apartment Maintenance study guide on one page, grouped by chapter. Tap a lesson link to read the full explanation.
52 facts · 7 chaptersFacts checked 2026-11-15
Chapter 1
Electrical Maintenance & Repair
Key takeaways
- An overload trips a breaker after a delay, a short circuit trips it at once, and a breaker that keeps tripping after the load is reduced is reporting a fault. → Overloads, short circuits and ground faults
- A GFCI senses current imbalance to protect people from shock, while an AFCI senses arcing to protect the building from fire. → Overloads, short circuits and ground faults
- On a receptacle, the white neutral goes to silver, the black hot goes to brass, and the ground goes to the green screw. → Wiring receptacles, switches and fixtures
- Prove a voltage tester on a known live source, test the circuit, then prove the tester again before trusting a dead reading. → Working safely: de-energize, test, then touch
- Current equals watts divided by volts, and resistance equals volts divided by amps, with power always off for any ohms reading. → Ohm's law, Watt's law and the multimeter
Common trap
- A larger breaker is never the fix for repeated tripping. The wire stays the same size, so a bigger breaker only removes the protection that was doing its job. → Overloads, short circuits and ground faults
- Answers that keep a damaged circuit in service, such as resetting until the breaker holds or working live with insulated gloves, are wrong whenever a safe de-energized option is listed. → Working safely: de-energize, test, then touch
Quick reference
| Fault | What happens | What responds |
|---|---|---|
| Overload | More load than the circuit was designed to carry | Breaker heats and trips after a delay |
| Short circuit | Current takes an unintended, very low-resistance path back to the source | Breaker trips at once |
| Ground fault | Current leaks out of the circuit, for example through a person to a wet surface | GFCI senses the imbalance and opens |
| Arc fault | Current jumps a gap and makes heat | AFCI recognizes the arcing pattern and opens |
Chapter 2
Plumbing Maintenance & Repair
Key takeaways
- A trap holds a water seal against sewer gas, and the vent lets air in so draining water cannot siphon that seal away. → Supply, distribution and drainage: traps and vents
- Stop a leak at the closest valve first, the fixture stop, then go up to the unit valve and the riser or main only if needed. → Shutoffs, leaks and water damage
- A problem at one fixture lives between that fixture's stop and its outlet, while symptoms at several fixtures point to a shared line. → Supply, distribution and drainage: traps and vents
- A dripping temperature and pressure relief valve is a symptom whose cause must be found, and its discharge is never capped or plugged. → Water heaters and joining pipe
- Clear drains mechanically with a plunger or auger, because chemical openers endanger the next worker and damage older pipe. → Toilets, faucets and clearing drains
Common trap
- When two or more fixtures are involved, answers about a single strainer, stopper or faucet part are wrong. Look at the line the fixtures share. → Supply, distribution and drainage: traps and vents
- Watch for answers that start with towels, photos or the building main. The exam wants the smallest valve that stops the water, then escalation one level at a time. → Shutoffs, leaks and water damage
- Chemical drain openers and sealant around a toilet base look like quick fixes, but both hide the problem. Caustic product left in a trap can burn the next person who opens it. → Toilets, faucets and clearing drains
Quick reference
| Symptom | Most likely cause |
|---|---|
| Sewer smell at a fixture that is rarely used | The trap seal evaporated; run water to refill it |
| Slow drain plus gurgling at a nearby fixture | Blocked vent or partial blockage in the shared branch |
| Water rises in a lower fixture when another drains | Blockage downstream of both, in the shared line |
Chapter 3
HVAC Service & When to Refer
Key takeaways
- Most no-cooling and frozen-coil calls start with airflow: a dirty or wrong-size filter, a blocked return, closed registers or a dirty coil. → Airflow: filters, returns, registers and coils
- Water dripping from the auxiliary drain or a unit stopped by its float switch means the primary condensate drain is blocked. → Condensate drains, pans and float switches
- Superheat is measured on the suction vapor and subcooling on the liquid line, and each is a difference from the saturation temperature. → The refrigeration cycle, superheat and EPA Section 608
- Under EPA Section 608, even attaching gauges to a sealed system requires certification, and refrigerant is recovered, never vented. → The refrigeration cycle, superheat and EPA Section 608
- For a gas smell, get people out without using switches or phones and call from outside; for a CO alarm with soot or a yellow flame, shut the appliance down and refer it. → Furnaces, heat pumps, boilers and gas safety
Common trap
- Closing registers in empty rooms does not push more air to the occupied ones for free. It adds resistance, the blower moves less air overall, and cooling capacity falls. → Airflow: filters, returns, registers and coils
- Superheat and subcooling are differences, not raw readings. Adding the two temperatures, or quoting the line temperature alone, is a planted wrong answer. → The refrigeration cycle, superheat and EPA Section 608
- Opening windows, running an exhaust fan or using a phone in the room are wrong first moves for a gas smell, because each keeps people inside or creates a spark. Leave first, then call. → Furnaces, heat pumps, boilers and gas safety
Quick reference
| What you see | What it means |
|---|---|
| Unit stopped, thermostat display normal, water in the pan | The float switch opened the control circuit to prevent water damage |
| Water dripping from the auxiliary line over a window | The primary drain is blocked; the backup line is warning you |
| Pan overflows though nothing is clogged | The drain trap lost its water seal, so cabinet air pressure blocks drainage |
Chapter 4
Appliances, Locks & Keys
Key takeaways
- A warm refrigerator with dirty condenser coils gets its coils cleaned before any part is condemned, and a sealed-system repair goes to an EPA 608 certified technician. → Refrigerators: moving heat out of the box
- Check gas connector joints with leak-detector solution and watch for bubbles, never with a flame. → Kitchen appliances: ranges, dishwashers, disposals and hoods
- Long drying times and a hot dryer cabinet point to a restricted exhaust duct, which is also the main dryer fire risk. → Washers and dryers
- When one load fails, test the parts only that load depends on; when everything is dead, test the part everything shares. → Reading schematics and testing parts
- A lost master key is reported at once so the affected locks can be re-keyed, and keys carry codes, not unit numbers. → Locks, keys and lockouts
Common trap
- Do not replace the thermal fuse or heating element first when drying is slow. A restricted duct causes both the slow drying and the heat that later opens the fuse, so it is cleared before any part is changed. → Washers and dryers
- Cutting a copy of a lost master key, waiting a few days for it to turn up, or telling only the maintenance team all leave every affected home exposed. Report it to management right away. → Locks, keys and lockouts
Quick reference
| Symptom | Check first |
|---|---|
| Box warm, compressor runs nonstop, condenser matted with dust | Clean the condenser coils |
| Fresh-food side warm, freezer cold, evaporator packed with frost | The defrost heater or the defrost control |
| Compressor failed, sealed system must be opened | Refer to an EPA 608 certified technician; management decides repair or replace |
Chapter 5
Interior & Exterior Repair
Key takeaways
- Drywall repairs use thin coats feathered wider each time, and large holes need wood backing behind the patch. → Drywall repair
- Prime every compound patch, use a stain-blocking sealer on water stains, and repaint the whole wall when a touch-up flashes. → Primer, paint and sheen
- Silicone suits wet tub joints but cannot be painted, while siliconized acrylic latex suits trim that will be painted. → Texture and caulk
- Fix the cause before the finish: tighten the top hinge, stop the leak before replacing a soft subfloor, and trace roof leaks uphill. → Doors, windows, cabinets and floors
- Leave suspect popcorn ceiling texture undisturbed and report it for asbestos testing. → Exterior, ladders and suspect materials
Common trap
- A heavier coat, a glossier sheen or a third coat of the same paint are tempting answers, but none of them fixes porosity, a water stain or poor adhesion. The correct answer is almost always a preparation step. → Primer, paint and sheen
- Running a fresh bead of silicone over the old one, or caulking a joint that is still damp, looks quick but fails: the new bead peels and mildew grows back underneath. → Texture and caulk
- Planing a door, sanding a cabinet corner or laying new flooring over a soft spot all change something permanently while the real cause, a loose hinge, a misadjusted hinge or a leak, stays in place. → Doors, windows, cabinets and floors
Quick reference
| Joint | Right sealant |
|---|---|
| Tub to tile surround | Silicone: watertight and mildew resistant, but not paintable |
| Baseboard or trim that will be painted | Siliconized acrylic latex caulk |
| Wide exterior joint that moves with the seasons | Backer rod, then a flexible exterior-rated sealant |
Chapter 6
Compliance, Safety & Fair Housing
Key takeaways
- Read the safety data sheet before using an unfamiliar chemical, and never mix cleaners such as bleach and ammonia. → Chemicals, PPE and sharps
- Only the worker who applied a lockout lock removes it, and an unventilated vault or pit is treated as a confined space. → Lockout/tagout, confined spaces and ladders
- Fair housing covers maintenance service, so requests are worked in order without regard to who lives in the home. → Fair housing in maintenance work
- A policy change is a reasonable accommodation, a physical change is a reasonable modification, and staff pass both requests to management. → Fair housing in maintenance work
- Presume lead paint in pre-1978 housing and treat older floor tile, mastic and popcorn texture as asbestos until tested. → Lead, asbestos, mold, pests and records
Common trap
- Having a coworker watch from above, holding the ladder base, or wrapping a crack with tape are planted answers. None of them controls the actual hazard, which is bad air in the space or a rail that can fail under load. → Lockout/tagout, confined spaces and ladders
- Answers that sound helpful can still be violations. Suggesting a ground-floor building, reserving a parking spot with a cone, or asking for medical records all put staff in a decision that belongs to management. → Fair housing in maintenance work
Quick reference
| Request | Type | Who pays under the federal Act |
|---|---|---|
| Reserved parking space near the door | Reasonable accommodation: a change in a rule or policy | Granted by the owner |
| Grab bars installed in the bathroom | Reasonable modification: a physical change to the home | Generally the resident, under the Fair Housing Act alone |
Chapter 7
Facilities Operations & Professionalism
Key takeaways
- Emergencies such as gas odors, flooding and loss of heat in freezing weather come first, and routine requests are worked oldest first no matter who calls most. → Prioritizing service requests and entering homes
- Enter only with permission on file, knock three times and keep announcing yourself as you move through the home. → Prioritizing service requests and entering homes
- A turn runs repairs, then paint, then cleaning, then carpet care, and ends with a punch list that is re-inspected until every item is closed. → Make-ready turns, inspections and curb appeal
- Free chlorine is the active sanitizer, and total minus free chlorine is combined chlorine that is already spent. → Pool and spa chemistry and math
- Unsafe conditions are reported and secured at once, and logs and incident reports record objective facts, not opinions. → Life safety, reporting and records
Common trap
- Painting first, cleaning carpet early or releasing a unit with minor items still open all look efficient, but each one guarantees rework or a poor first impression for the new resident. → Make-ready turns, inspections and curb appeal
- A sign asking residents to pull the gate shut, a prop holding a door, or a note for next month's walk all leave the hazard in service. So do schedule-based extinguisher discharges or refills; the monthly check is visual only, and recharging follows use or what an inspection or maintenance finds. → Life safety, reporting and records
Quick reference
| Reading | What it means or what fixes it |
|---|---|
| pH above the target range | Add an acid such as sodium bisulfate; soda ash and baking soda raise it |
| Total alkalinity | Buffering capacity that keeps pH from swinging |
| Calcium hardness | Dissolved calcium that can form scale |