Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/32 ▾
  1. 1.Electrical Maintenance & Repair0/4
    1. Overloads, short circuits and ground faults
    2. Wiring receptacles, switches and fixtures
    3. Working safely: de-energize, test, then touch
    4. Ohm's law, Watt's law and the multimeter
  2. 2.Plumbing Maintenance & Repair0/4
    1. Supply, distribution and drainage: traps and vents
    2. Shutoffs, leaks and water damage
    3. Toilets, faucets and clearing drains
    4. Water heaters and joining pipe
  3. 3.HVAC Service & When to Refer0/5
    1. Airflow: filters, returns, registers and coils
    2. Condensate drains, pans and float switches
    3. Thermostats and controls
    4. The refrigeration cycle, superheat and EPA Section 608
    5. Furnaces, heat pumps, boilers and gas safety
  4. 4.Appliances, Locks & Keys0/5
    1. Refrigerators: moving heat out of the box
    2. Kitchen appliances: ranges, dishwashers, disposals and hoods
    3. Washers and dryers
    4. Reading schematics and testing parts
    5. Locks, keys and lockouts
  5. 5.Interior & Exterior Repair0/5
    1. Drywall repair
    2. Primer, paint and sheen
    3. Texture and caulk
    4. Doors, windows, cabinets and floors
    5. Exterior, ladders and suspect materials
  6. 6.Compliance, Safety & Fair Housing0/4
    1. Chemicals, PPE and sharps
    2. Lockout/tagout, confined spaces and ladders
    3. Fair housing in maintenance work
    4. Lead, asbestos, mold, pests and records
  7. 7.Facilities Operations & Professionalism0/5
    1. Prioritizing service requests and entering homes
    2. Make-ready turns, inspections and curb appeal
    3. Preventive maintenance, repair or replace, and contractors
    4. Pool and spa chemistry and math
    5. Life safety, reporting and records
Saved in this browser. Move it to another device →
← Plumbing Maintenance & Repair

Chapter 2 · Lesson 4 of 4

Water heaters and joining pipe

1 min read

The temperature and pressure relief valve is a storage water heater's last protection against rupture. Its outlet must stay open, with no cap, plug or valve in the discharge line.

A steady drip means the valve is relieving for a reason, such as a setting that is too high, thermal expansion or a fouled seat, and the technician finds and fixes that cause.

  • Fill an electric water heater completely and purge air through an open hot faucet before turning power on. An element energized without water around it burns out almost at once.
  • Rumbling and popping during heating come from sediment on the tank bottom. Flushing the tank on a schedule removes it, and the anode rod is inspected on the same visit.
  • Joining copper to galvanized steel needs a dielectric union, which keeps the two metals apart so galvanic corrosion does not eat the joint.

Example: after replacing an electric water heater, a technician opens the supply valve and a hot faucet, waits until water runs steadily with no spurting air, and only then turns the breaker on. If the relief valve begins to drip later, the technician checks the setting and the cause rather than capping the discharge pipe.

Check yourself

1. A storage water heater's temperature and pressure relief valve is dripping steadily. What is the correct response?

2. A storage water heater rumbles and pops during a heating cycle. What is the MOST likely cause and the correct preventive action?