Furnaces, heat pumps, boilers and gas safety
1 min read
In an induced-draft gas furnace, the first event after a call for heat is the inducer motor starting, and a pressure switch proves the vent is drawing.
Only then does the igniter heat, the gas valve open and the burners light. The flame sensor proves flame, and the blower starts after a short delay so it does not push cold air into the home.
- A heat pump that stops its outdoor fan for a few minutes while steam rises from the coil is in a normal defrost cycle.
- A cold top-floor baseboard with gurgling pipes has trapped air; bleed it at the baseboard bleeder valve.
- A brief burning-dust smell on the first heating run of the season, with warm supply air, is normal.
Two situations are never service adjustments. A gas smell means an ignitable mixture may be present, so the technician uses no switches, phones or radios, gets everyone out and calls from outside.
A carbon monoxide alarm together with soot or a yellow, rolling flame means incomplete combustion: shut the furnace down, ventilate and leave it off until a licensed contractor evaluates it.
Check yourself
1. While checking a gas furnace in an occupied apartment, a technician smells gas near the equipment. What is the correct sequence of actions?
2. A resident's thermostat calls for heat on an induced-draft gas furnace with hot surface ignition. Which event should happen first in the furnace's normal sequence of operation?