Wiring receptacles, switches and fixtures
1 min read
In normal use, current leaves the panel on the hot conductor and returns on the grounded conductor, called the neutral. The equipment grounding conductor and bonding tie all metal boxes and enclosures together so that a fault has a low-resistance path back to the source and the breaker can open.
The ground carries current only during a fault, so it is never joined to the neutral at a receptacle or used as a return path. If it were, normal working current would flow over metal parts a person can touch.
- Receptacle terminals: silver takes the white neutral, brass takes the black hot, green takes the ground. This keeps polarity correct.
- A white conductor wrapped with black tape has been re-identified as a hot. Color is only a hint, so confirm with a tester before touching it.
- A light controlled from two places uses a pair of three-way switches, each with three screw terminals: one common and two travelers.
- Conductors that are too short get pigtails of the same gauge and color, and every splice stays inside a covered box.
Lighting failures follow the same logic. A fluorescent fixture that hums loudly and leaks dark oily residue points to a failing ballast. An integrated LED fixture has no ballast or starter; its power comes through a driver, so flickering followed by darkness usually means the driver has failed.
Check yourself
1. A technician is replacing a damaged duplex receptacle in an apartment. Where does each conductor land on the new device?
2. Which statement correctly describes the roles of the grounded (neutral) conductor and of bonding?