Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/32 ▾
  1. 1.Electrical Maintenance & Repair0/4
    1. Overloads, short circuits and ground faults
    2. Wiring receptacles, switches and fixtures
    3. Working safely: de-energize, test, then touch
    4. Ohm's law, Watt's law and the multimeter
  2. 2.Plumbing Maintenance & Repair0/4
    1. Supply, distribution and drainage: traps and vents
    2. Shutoffs, leaks and water damage
    3. Toilets, faucets and clearing drains
    4. Water heaters and joining pipe
  3. 3.HVAC Service & When to Refer0/5
    1. Airflow: filters, returns, registers and coils
    2. Condensate drains, pans and float switches
    3. Thermostats and controls
    4. The refrigeration cycle, superheat and EPA Section 608
    5. Furnaces, heat pumps, boilers and gas safety
  4. 4.Appliances, Locks & Keys0/5
    1. Refrigerators: moving heat out of the box
    2. Kitchen appliances: ranges, dishwashers, disposals and hoods
    3. Washers and dryers
    4. Reading schematics and testing parts
    5. Locks, keys and lockouts
  5. 5.Interior & Exterior Repair0/5
    1. Drywall repair
    2. Primer, paint and sheen
    3. Texture and caulk
    4. Doors, windows, cabinets and floors
    5. Exterior, ladders and suspect materials
  6. 6.Compliance, Safety & Fair Housing0/4
    1. Chemicals, PPE and sharps
    2. Lockout/tagout, confined spaces and ladders
    3. Fair housing in maintenance work
    4. Lead, asbestos, mold, pests and records
  7. 7.Facilities Operations & Professionalism0/5
    1. Prioritizing service requests and entering homes
    2. Make-ready turns, inspections and curb appeal
    3. Preventive maintenance, repair or replace, and contractors
    4. Pool and spa chemistry and math
    5. Life safety, reporting and records
Saved in this browser. Move it to another device →
← Electrical Maintenance & Repair

Chapter 1 · Lesson 3 of 4

Working safely: de-energize, test, then touch

1 min read

The exam returns again and again to one rule: remove the energy before you handle anything. When a receptacle is wet from a leak, warm, scorched or giving off a burning smell, the first step is to open the circuit at the panel and verify the device is dead.

Drying, tightening or testing polarity comes later. Heat and scorching mean a connection is already arcing or overheating, which is an active fire hazard.

A silent tester proves nothing by itself, because a tester with a dead battery looks exactly like a dead circuit. Use the live-dead-live check: prove the tester on a known live source, test the circuit, then prove the tester again. Never check for voltage by touch.

  • Several dead outlets in one room: check the panel and any upstream GFCI first, then test at the outlets, before opening any wiring.
  • Dull silver branch wiring with darkened terminals suggests aluminum wiring. Stop and have a licensed electrician evaluate it.

Example: during a make-ready a technician finds a receptacle cover plate discolored brown around one slot, and the plug of a lamp left behind is warm.

The right order is to switch off that breaker, prove the tester, confirm the outlet is dead, and only then pull the device to look for a loose or overheated termination. Replacing the cover plate or asking the next resident to use fewer appliances leaves the hazard in the wall.

Check yourself

1. What is the correct way to use a voltage tester before working on a circuit that has been switched off?

2. A resident reports a burning smell, and the technician finds a receptacle that is warm to the touch and scorched around one slot. What should the technician do FIRST?

Facts checked 2026-11-15 · Sources: NAAEI: Certificate for Apartment Maintenance Technicians (CAMT), OSHA 29 CFR 1910.147: Control of hazardous energy (lockout/tagout)