Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/32 ▾
  1. 1.Electrical Maintenance & Repair0/4
    1. Overloads, short circuits and ground faults
    2. Wiring receptacles, switches and fixtures
    3. Working safely: de-energize, test, then touch
    4. Ohm's law, Watt's law and the multimeter
  2. 2.Plumbing Maintenance & Repair0/4
    1. Supply, distribution and drainage: traps and vents
    2. Shutoffs, leaks and water damage
    3. Toilets, faucets and clearing drains
    4. Water heaters and joining pipe
  3. 3.HVAC Service & When to Refer0/5
    1. Airflow: filters, returns, registers and coils
    2. Condensate drains, pans and float switches
    3. Thermostats and controls
    4. The refrigeration cycle, superheat and EPA Section 608
    5. Furnaces, heat pumps, boilers and gas safety
  4. 4.Appliances, Locks & Keys0/5
    1. Refrigerators: moving heat out of the box
    2. Kitchen appliances: ranges, dishwashers, disposals and hoods
    3. Washers and dryers
    4. Reading schematics and testing parts
    5. Locks, keys and lockouts
  5. 5.Interior & Exterior Repair0/5
    1. Drywall repair
    2. Primer, paint and sheen
    3. Texture and caulk
    4. Doors, windows, cabinets and floors
    5. Exterior, ladders and suspect materials
  6. 6.Compliance, Safety & Fair Housing0/4
    1. Chemicals, PPE and sharps
    2. Lockout/tagout, confined spaces and ladders
    3. Fair housing in maintenance work
    4. Lead, asbestos, mold, pests and records
  7. 7.Facilities Operations & Professionalism0/5
    1. Prioritizing service requests and entering homes
    2. Make-ready turns, inspections and curb appeal
    3. Preventive maintenance, repair or replace, and contractors
    4. Pool and spa chemistry and math
    5. Life safety, reporting and records
Saved in this browser. Move it to another device →
← Compliance, Safety & Fair Housing

Chapter 6 · Lesson 2 of 4

Lockout/tagout, confined spaces and ladders

1 min read

A lockout lock is a personal guarantee that the worker who applied it is clear of the equipment.

Under OSHA's hazardous energy rule, only the worker who applied the lock removes it. If that person is unavailable, removal follows the employer's written exception procedure, never the convenience of whoever needs the equipment next, whether that is another technician, a vendor or a resident.

  • A space big enough to enter, with limited ways in and out and not built for continuous occupancy, is a confined space. An unventilated pump vault can hold air that is low in oxygen or toxic with no warning.
  • Entry needs air testing, ventilation, an attendant and a rescue plan, so the technician stops and reports rather than climbing in.
  • A ladder with a structural defect, such as a cracked rail, is tagged out of service and removed until repaired or replaced.

Example: a technician locks the disconnect for a rooftop unit at the end of a shift, planning to finish in the morning. That evening a vendor arrives to service the same unit. The vendor waits, and the lock stays on until the technician who applied it returns or the employer's documented exception procedure is followed.

Check yourself

1. A technician locked and tagged the disconnect for a rooftop unit and then left for the day with the lock still in place. Who is permitted to remove that lock?

2. A technician drops a wrench into an underground pump vault that has a single access hatch and no ventilation. What is the MOST appropriate action?

Facts checked 2026-11-15 · Sources: OSHA: Hazard Communication, HUD: Fair Housing and Equal Opportunity, EPA: Lead Renovation, Repair and Painting Program

CAMT Apartment Maintenance cheat sheet: every key fact on one page →