Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/32 ▾

0 of 32 lessons finished

Continue: Thermostats and controls
  1. 1.Electrical Maintenance & Repair0/4
    1. Overloads, short circuits and ground faults
    2. Wiring receptacles, switches and fixtures
    3. Working safely: de-energize, test, then touch
    4. Ohm's law, Watt's law and the multimeter
  2. 2.Plumbing Maintenance & Repair0/4
    1. Supply, distribution and drainage: traps and vents
    2. Shutoffs, leaks and water damage
    3. Toilets, faucets and clearing drains
    4. Water heaters and joining pipe
  3. 3.HVAC Service & When to Refer0/5
    1. Airflow: filters, returns, registers and coils
    2. Condensate drains, pans and float switches
    3. Thermostats and controls
    4. The refrigeration cycle, superheat and EPA Section 608
    5. Furnaces, heat pumps, boilers and gas safety
  4. 4.Appliances, Locks & Keys0/5
    1. Refrigerators: moving heat out of the box
    2. Kitchen appliances: ranges, dishwashers, disposals and hoods
    3. Washers and dryers
    4. Reading schematics and testing parts
    5. Locks, keys and lockouts
  5. 5.Interior & Exterior Repair0/5
    1. Drywall repair
    2. Primer, paint and sheen
    3. Texture and caulk
    4. Doors, windows, cabinets and floors
    5. Exterior, ladders and suspect materials
  6. 6.Compliance, Safety & Fair Housing0/4
    1. Chemicals, PPE and sharps
    2. Lockout/tagout, confined spaces and ladders
    3. Fair housing in maintenance work
    4. Lead, asbestos, mold, pests and records
  7. 7.Facilities Operations & Professionalism0/5
    1. Prioritizing service requests and entering homes
    2. Make-ready turns, inspections and curb appeal
    3. Preventive maintenance, repair or replace, and contractors
    4. Pool and spa chemistry and math
    5. Life safety, reporting and records
Saved in this browser. Move it to another device →
← HVAC Service & When to Refer

Chapter 3 · Lesson 2 of 5

Condensate drains, pans and float switches

1 min read

A running cooling coil pulls moisture out of the air all day, and that water must leave through the drain pan and drain line. When the line clogs, the pan fills and spills, and in a stacked building the first sign is often a brown stain on the ceiling of the apartment below.

That is why a ceiling stain under an air handler closet sends the technician straight to the condensate drain, the pan and the pan overflow.

What you seeWhat it means
Unit stopped, thermostat display normal, water in the panThe float switch opened the control circuit to prevent water damage
Water dripping from the auxiliary line over a windowThe primary drain is blocked; the backup line is warning you
Pan overflows though nothing is cloggedThe drain trap lost its water seal, so cabinet air pressure blocks drainage

The trap on a condensate line is there because the blower holds the cabinet at a different pressure from the room. Without a water seal, air pushes or pulls through the drain instead of letting water out. The fix for every row above is to clear and flush the primary drain, empty the pan and confirm the float switch resets.

Check yourself

1. Water is dripping from the small auxiliary drain line that ends above a window on the outside of the building. What does this tell the technician?

2. A resident on a lower floor reports a brown stain spreading across the bedroom ceiling. The apartment directly above has its air handler in a closet over that bedroom, and the air conditioner is running. What should the technician check first?

Facts checked 2026-11-15 · Sources: NAAEI: Certificate for Apartment Maintenance Technicians (CAMT), EPA: Section 608 of the Clean Air Act (refrigerant management), EPA: Universal waste (mercury-containing equipment)