Chapters0/32 ▾
Chapter 4 · Lesson 1 of 5
Refrigerators: moving heat out of the box
1 min read
A refrigerator does not make cold; it moves heat from inside the cabinet to the room.
The compressor raises the refrigerant's pressure, the condenser coil hands its heat to the room air, the metering device (such as a capillary tube) drops the pressure so the liquid can boil at a low temperature, and the evaporator absorbs heat from inside the box. Fans only move air across the coils.
| Symptom | Check first |
|---|---|
| Box warm, compressor runs nonstop, condenser matted with dust | Clean the condenser coils |
| Fresh-food side warm, freezer cold, evaporator packed with frost | The defrost heater or the defrost control |
| Compressor failed, sealed system must be opened | Refer to an EPA 608 certified technician; management decides repair or replace |
Example: a resident reports that milk spoils in two days while ice cream stays hard. The technician removes the rear freezer panel and finds the evaporator coil buried in frost, which blocks the air that normally flows to the fresh-food side. Because the frost never clears, the defrost system is tested before anything else is replaced.
When the sealed system itself has failed, the technician's job changes. Without EPA Section 608 certification, a technician may not recover, add or charge refrigerant, and that includes installing a piercing valve as a stopgap. Because a compressor job can cost more than the refrigerator is worth, the repair-or-replace decision goes to management under company policy.
Check yourself
1. A resident reports the refrigerator is warm inside. The compressor runs almost continuously, the freezer is only slightly cold, and the condenser coils are matted with dust and pet hair. What is the most likely cause?
2. Diagnosis shows that a refrigerator's compressor has failed and the sealed refrigerant system must be opened. The technician is not certified to handle refrigerant. What is the correct action?
Facts checked 2026-11-15 · Sources: NAAEI: Certificate for Apartment Maintenance Technicians (CAMT), EPA: Section 608 of the Clean Air Act (refrigerant management)
CAMT Apartment Maintenance cheat sheet: every key fact on one page →