Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/32 ▾
  1. 1.Electrical Maintenance & Repair0/4
    1. Overloads, short circuits and ground faults
    2. Wiring receptacles, switches and fixtures
    3. Working safely: de-energize, test, then touch
    4. Ohm's law, Watt's law and the multimeter
  2. 2.Plumbing Maintenance & Repair0/4
    1. Supply, distribution and drainage: traps and vents
    2. Shutoffs, leaks and water damage
    3. Toilets, faucets and clearing drains
    4. Water heaters and joining pipe
  3. 3.HVAC Service & When to Refer0/5
    1. Airflow: filters, returns, registers and coils
    2. Condensate drains, pans and float switches
    3. Thermostats and controls
    4. The refrigeration cycle, superheat and EPA Section 608
    5. Furnaces, heat pumps, boilers and gas safety
  4. 4.Appliances, Locks & Keys0/5
    1. Refrigerators: moving heat out of the box
    2. Kitchen appliances: ranges, dishwashers, disposals and hoods
    3. Washers and dryers
    4. Reading schematics and testing parts
    5. Locks, keys and lockouts
  5. 5.Interior & Exterior Repair0/5
    1. Drywall repair
    2. Primer, paint and sheen
    3. Texture and caulk
    4. Doors, windows, cabinets and floors
    5. Exterior, ladders and suspect materials
  6. 6.Compliance, Safety & Fair Housing0/4
    1. Chemicals, PPE and sharps
    2. Lockout/tagout, confined spaces and ladders
    3. Fair housing in maintenance work
    4. Lead, asbestos, mold, pests and records
  7. 7.Facilities Operations & Professionalism0/5
    1. Prioritizing service requests and entering homes
    2. Make-ready turns, inspections and curb appeal
    3. Preventive maintenance, repair or replace, and contractors
    4. Pool and spa chemistry and math
    5. Life safety, reporting and records
Saved in this browser. Move it to another device →
← Appliances, Locks & Keys

Chapter 4 · Lesson 1 of 5

Refrigerators: moving heat out of the box

1 min read

A refrigerator does not make cold; it moves heat from inside the cabinet to the room.

The compressor raises the refrigerant's pressure, the condenser coil hands its heat to the room air, the metering device (such as a capillary tube) drops the pressure so the liquid can boil at a low temperature, and the evaporator absorbs heat from inside the box. Fans only move air across the coils.

SymptomCheck first
Box warm, compressor runs nonstop, condenser matted with dustClean the condenser coils
Fresh-food side warm, freezer cold, evaporator packed with frostThe defrost heater or the defrost control
Compressor failed, sealed system must be openedRefer to an EPA 608 certified technician; management decides repair or replace

Example: a resident reports that milk spoils in two days while ice cream stays hard. The technician removes the rear freezer panel and finds the evaporator coil buried in frost, which blocks the air that normally flows to the fresh-food side. Because the frost never clears, the defrost system is tested before anything else is replaced.

When the sealed system itself has failed, the technician's job changes. Without EPA Section 608 certification, a technician may not recover, add or charge refrigerant, and that includes installing a piercing valve as a stopgap. Because a compressor job can cost more than the refrigerator is worth, the repair-or-replace decision goes to management under company policy.

Check yourself

1. A resident reports the refrigerator is warm inside. The compressor runs almost continuously, the freezer is only slightly cold, and the condenser coils are matted with dust and pet hair. What is the most likely cause?

2. Diagnosis shows that a refrigerator's compressor has failed and the sealed refrigerant system must be opened. The technician is not certified to handle refrigerant. What is the correct action?

Facts checked 2026-11-15 · Sources: NAAEI: Certificate for Apartment Maintenance Technicians (CAMT), EPA: Section 608 of the Clean Air Act (refrigerant management)

CAMT Apartment Maintenance cheat sheet: every key fact on one page →