    1. Overloads, short circuits and ground faults
    2. Wiring receptacles, switches and fixtures
    3. Working safely: de-energize, test, then touch
    4. Ohm's law, Watt's law and the multimeter
  2. 2.Plumbing Maintenance & Repair0/4
    1. Supply, distribution and drainage: traps and vents
    2. Shutoffs, leaks and water damage
    3. Toilets, faucets and clearing drains
    4. Water heaters and joining pipe
  3. 3.HVAC Service & When to Refer0/5
    1. Airflow: filters, returns, registers and coils
    2. Condensate drains, pans and float switches
    3. Thermostats and controls
    4. The refrigeration cycle, superheat and EPA Section 608
    5. Furnaces, heat pumps, boilers and gas safety
  4. 4.Appliances, Locks & Keys0/5
    1. Refrigerators: moving heat out of the box
    2. Kitchen appliances: ranges, dishwashers, disposals and hoods
    3. Washers and dryers
    4. Reading schematics and testing parts
    5. Locks, keys and lockouts
  5. 5.Interior & Exterior Repair0/5
    1. Drywall repair
    2. Primer, paint and sheen
    3. Texture and caulk
    4. Doors, windows, cabinets and floors
    5. Exterior, ladders and suspect materials
  6. 6.Compliance, Safety & Fair Housing0/4
    1. Chemicals, PPE and sharps
    2. Lockout/tagout, confined spaces and ladders
    3. Fair housing in maintenance work
    4. Lead, asbestos, mold, pests and records
  7. 7.Facilities Operations & Professionalism0/5
    1. Prioritizing service requests and entering homes
    2. Make-ready turns, inspections and curb appeal
    3. Preventive maintenance, repair or replace, and contractors
    4. Pool and spa chemistry and math
    5. Life safety, reporting and records
Saved in this browser. Move it to another device →
← Back

Study guide · Chapter 1 of 7

Electrical Maintenance & Repair Study Guide — CAMT Apartment Maintenance

26 free practice questions

The electrical questions on the CAMT exam test whether you can tell circuit faults apart, replace devices with the wires in the right places, and work on a circuit only after you have proved it is dead. A few questions also ask you to use Ohm's law and Watt's law or to read a multimeter. Electrical codes are adopted differently from place to place, so the exam tests the reasons behind the rules, not code numbers.

Key takeaways

  • An overload trips a breaker after a delay, a short circuit trips it at once, and a breaker that keeps tripping after the load is reduced is reporting a fault.
  • A GFCI senses current imbalance to protect people from shock, while an AFCI senses arcing to protect the building from fire.
  • On a receptacle, the white neutral goes to silver, the black hot goes to brass, and the ground goes to the green screw.
  • Prove a voltage tester on a known live source, test the circuit, then prove the tester again before trusting a dead reading.
  • Current equals watts divided by volts, and resistance equals volts divided by amps, with power always off for any ohms reading.

Lessons in this chapter

4 short lessons · 4 min read

  1. 1Overloads, short circuits and ground faults1 min
  2. 2Wiring receptacles, switches and fixtures1 min
  3. 3Working safely: de-energize, test, then touch1 min
  4. 4Ohm's law, Watt's law and the multimeter1 min
View all questions & answers →

Facts checked 2026-11-15 · Sources: NAAEI: Certificate for Apartment Maintenance Technicians (CAMT), OSHA 29 CFR 1910.147: Control of hazardous energy (lockout/tagout)

CAMT Apartment Maintenance cheat sheet: every key fact on one page →Next chapter: Plumbing Maintenance & Repair →

Practice questions based on the published NAAEI CAMT domains — Essential Trade Skills, Compliance, Facilities Operations, and Professional Development & Collaboration — and on standard trade practice. CAMT and NAAEI are marks of the National Apartment Association; this site is not affiliated with or endorsed by NAA or NAAEI. Code requirements, licensing boundaries and permit rules vary by jurisdiction and revise on a cycle, so none is tested here as a recalled figure — always verify the code having jurisdiction and use a licensed contractor where the work requires one. Confirm current program requirements with NAAEI before testing. About the CAMT credential →