Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Structure & Foundation0/5
    1. Footings, soil movement and foundation crack patterns
    2. Water below grade and in crawl spaces
    3. Load path, columns and floor framing
    4. Roof framing: rafters, ridges and trusses
    5. Decay and wood-destroying organisms
  2. 2.Roofing, Exterior & Site0/5
    1. Roof coverings: how they keep water out and how they fail
    2. Flashings and roof penetrations
    3. Roof drainage, ice dams and chimney tops
    4. Walls, cladding and windows as drained assemblies
    5. Decks, grading and retaining walls
  3. 3.Electrical Systems0/5
    1. Service entrance and capacity
    2. Grounding, bonding and the neutral
    3. Inside the panel: overcurrent protection and terminations
    4. Ground-fault, arc-fault and receptacle testing
    5. Older wiring, workmanship defects and generators
  4. 4.Plumbing Systems0/4
    1. Water supply and piping materials
    2. Traps, vents and drain defects
    3. Water heaters, relief valves and gas connections
    4. Cross-connections, backflow and fixture leaks
  5. 5.HVAC, Insulation & Ventilation0/5
    1. Furnace combustion safety
    2. Venting, draft and house depressurization
    3. Boilers, heat pumps and air conditioning
    4. Insulation, air barriers and vapor retarders
    5. Attic ventilation, crawl spaces and exhaust ducts
  6. 6.Standards, Ethics & Reporting0/5
    1. What a home inspection is and is not
    2. Material defects and how to classify findings
    3. Writing the report: methods, limits and wording
    4. Exclusions, environmental hazards and immediate dangers
    5. Agreements, confidentiality and conflicts of interest
Saved in this browser. Move it to another device →
← Standards, Ethics & Reporting

Chapter 6 · Lesson 3 of 5

Writing the report: methods, limits and wording

1 min read

A good entry names the component, the condition, its location, the implication and a recommendation, and stops there.

Example: rust and mineral deposits at the cold-water connection on a water heater become a line stating the corrosion at that connection, that it indicates past leakage, and that a qualified plumber should evaluate it. The entry does not quote a repair price, blame a past owner for a cause nobody saw, or say how many years the tank has left.

  • State the method: a roof viewed from a ladder at the eaves and from the ground was inspected, and the report says how and what that limited.
  • State what was not inspected and why: a flooded crawl space viewed only from the opening is reported that way, never as satisfactory and never left out.
  • Treat instruments honestly: an infrared camera shows temperature differences, not moisture, so a cool pattern is an anomaly to confirm with another method.
  • A dry stain is still reported: a dry meter reading shows the moment, not a repair, so describe the stain and recommend evaluation of possible sources.

Check yourself

1. Standing water covers the crawl space floor and the inspector judges entry to be unsafe. What is the correct handling of this situation?

2. The inspector observes rust staining and mineral deposit at the cold-water connection on top of a storage water heater, with a dried streak running down the tank jacket. Which written report entry is most appropriate?

Facts checked 2026-11-15 · Sources: InterNACHI Home Inspection Standards of Practice, InterNACHI Code of Ethics for Home Inspectors, ASHI Standard of Practice for Home Inspection, EPA: Health Risk of Radon, EPA: Protect Your Family from Sources of Lead