Home Inspector Practice Test (NHIE) Cheat Sheet: Key Facts
Every key takeaway and common trap from the Home Inspector Practice Test (NHIE) study guide on one page, grouped by chapter. Tap a lesson link to read the full explanation.
41 facts · 6 chaptersFacts checked 2026-11-15
Chapter 1
Structure & Foundation
Key takeaways
- A footing spreads a concentrated wall load over enough soil that the bearing pressure stays within what the soil can carry. → Footings, soil movement and foundation crack patterns
- A horizontal mid-height crack with inward bowing points to lateral soil pressure, while stair-step or tapered cracks point to settlement or heave. → Footings, soil movement and foundation crack patterns
- Most wet basements are surface-water problems, so roof drainage and grading are corrected first. → Water below grade and in crawl spaces
- Every load needs a continuous path to the soil, and a cut truss member or a post that lands on joists breaks that path. → Load path, columns and floor framing
- Inspectors report conditions conducive to wood-destroying organisms and refer identification and treatment to a pest specialist. → Decay and wood-destroying organisms
Common trap
- Distractors often swap the crack signatures, calling a horizontal bowed crack settlement or a seasonal crack curing shrinkage. Match direction and behavior to the force: sideways force makes horizontal cracks, vertical movement makes stair-step or tapered cracks, and only moisture-driven soil movement reverses with the seasons. → Footings, soil movement and foundation crack patterns
- A general home inspection is not a wood-destroying-organism inspection. Answers that declare an active infestation, prescribe chemical treatment, or leave conducive conditions out because nothing was seen are all wrong. Report what is visible and the conditions that favor organisms, then refer to a qualified pest professional. → Decay and wood-destroying organisms
Quick reference
| What you see | Most likely mechanism |
|---|---|
| Horizontal crack near mid-height of a block wall, upper part pushed inward | Lateral soil pressure, often worse when the backfill is saturated |
| Stair-step crack at a corner, wider at the top, with a sloping floor | Differential settlement of that corner |
| Fine, even-width vertical cracks with no offset in a new concrete wall | Curing shrinkage; describe and recommend monitoring |
| Cracks that open in dry spells and close after wet seasons | Expansive clay shrinking and swelling |
Chapter 2
Roofing, Exterior & Site
Key takeaways
- Lapped coverings such as shingles and tile only shed water, so shallow slopes need a continuous membrane instead. → Roof coverings: how they keep water out and how they fail
- Flashings work by shingle-fashion layering, upper over lower, and sealant is a maintenance item, never the primary defense. → Flashings and roof penetrations
- Ice dams are a heat-loss problem, and the durable fix is air sealing, insulation and balanced attic ventilation. → Roof drainage, ice dams and chimney tops
- Walls are drained assemblies, so blocked brick weeps or a reverse-lapped barrier send water into the sheathing. → Walls, cladding and windows as drained assemblies
- A deck ledger with nails and no flashing, or a beam hanging on toe-nails, is a safety defect to report before use. → Decks, grading and retaining walls
Common trap
- Watch for answers that praise a single continuous piece because it has fewer joints, or accept sealant because it matches the mortar color. Fewer joints do not help if the layering is wrong, and the inspector reports and refers instead of applying cement during the inspection. → Flashings and roof penetrations
Quick reference
| Observation | What it points to |
|---|---|
| Soft, round bruises scattered over every slope | Hail impact |
| Scuffing along the route from ladder to rooftop equipment | Foot traffic |
| Rust rings and raised screws on a metal panel roof | Hardened washers and thermal movement; each screw is an open penetration |
| Water still standing on a low-slope roof days after rain, alligatored surface, blistered laps | Drainage deficiency and aging membrane; refer to a roofing contractor |
Chapter 3
Electrical Systems
Key takeaways
- Service capacity is set by the lowest-rated component in the chain, and a home inspection does not include a load calculation. → Service entrance and capacity
- Neutral and ground are bonded at the service disconnect only, so a bonded subpanel puts working current on metal parts. → Grounding, bonding and the neutral
- A breaker protects the wire, not the appliance, except where listed air-conditioning equipment is protected according to its nameplate. → Inside the panel: overcurrent protection and terminations
- Ground-fault protection protects people from shock and arc-fault protection reduces fire risk, so neither replaces the other. → Ground-fault, arc-fault and receptacle testing
- A portable generator cord-connected to a branch circuit with no transfer equipment can backfeed and kill line workers. → Older wiring, workmanship defects and generators
Common trap
- When a panel is rusted, wet or actively stained, the correct answer leaves the dead front on, reports what was seen and states that the interior was not inspected and why. Answers that shut off the main first, or skip the panel without explanation, are both wrong. → Inside the panel: overcurrent protection and terminations
- Never treat a correct reading on a three-light tester as proof of a ground, and never accept a neutral-to-ground jumper as a fix. Arc-fault protection cannot create an equipment ground either; it only addresses the fire risk of arcing. → Ground-fault, arc-fault and receptacle testing
Quick reference
| Conductor | Normal job |
|---|---|
| Grounded conductor (neutral) | Carries return current all the time as part of the circuit |
| Equipment grounding conductor | Idle by design; during a fault it gives a low-impedance path so the breaker trips fast |
Chapter 4
Plumbing Systems
Key takeaways
- Old galvanized pipe narrows from the inside, so the fixture at the end of the longest run loses flow first. → Water supply and piping materials
- The trap blocks sewer gas and the vent protects the trap by admitting air so the seal is not siphoned or blown out. → Traps, vents and drain defects
- Back-siphonage is driven by low supply pressure and backpressure by higher downstream pressure, as at a boiler. → Cross-connections, backflow and fixture leaks
- A relief valve discharge line runs full size, with no valve, trap or threads, downward to where discharge will be seen. → Water heaters, relief valves and gas connections
- Spillage at a draft hood after the vent warms up is a carbon monoxide hazard to report at once, not adjust. → Water heaters, relief valves and gas connections
Common trap
- Do not confuse the jobs of the trap and the vent. Distractors claim the vent blocks sewer gas, or that a second trap adds protection. The trap blocks gas; the vent only protects the trap. When a fixture is used every day, evaporation is the wrong answer for a lost seal. → Traps, vents and drain defects
- A single check valve is not the answer for a boiler connection, and a hose that is only a problem while the faucet runs is a false claim: a submerged outlet is a cross-connection whenever supply pressure can drop. → Cross-connections, backflow and fixture leaks
Quick reference
| Material and finding | Mechanism |
|---|---|
| Old galvanized steel, weak flow at the farthest fixture | Internal rust and scale, cumulative along the run |
| Copper, pinholes on elbows just past a partly closed valve | Erosion corrosion from high velocity and turbulence |
| PEX in direct sunlight at a crawl-space vent | Ultraviolet light embrittles the polymer |
| Copper joined straight to galvanized, heavy corrosion at the joint | Galvanic corrosion; a dielectric fitting breaks the circuit |
| Backflow type | Cause | Example |
|---|---|---|
| Back-siphonage | Negative or reduced pressure on the supply side | Hose submerged in a tub |
| Backpressure | Downstream pressure higher than supply pressure | Boiler make-up water line; needs a listed backflow preventer, not just a check valve |
Chapter 5
HVAC, Insulation & Ventilation
Key takeaways
- A flame that shifts or turns yellow when the blower starts, along with rust and soot, points to a possible heat exchanger breach that needs referral. → Furnace combustion safety
- Atmospheric vents rely on weak buoyant draft, so exhaust fans or an oversized orphaned chimney can reverse them and spill flue gas. → Venting, draft and house depressurization
- The temperature split is a screening check, and an out-of-range result is reported for evaluation, not diagnosed as low charge. → Boilers, heat pumps and air conditioning
- Insulation only resists conduction, so it needs a continuous, aligned air barrier to perform. → Insulation, air barriers and vapor retarders
- Bath fans and dryers must exhaust outdoors, and a vented attic needs open intake at the eaves as well as exhaust high, such as at the ridge. → Attic ventilation, crawl spaces and exhaust ducts
Common trap
- Answers that attach gauges to check refrigerant charge, bypass the thermostat at the outdoor disconnect, or adjust a gas valve are always outside a visual inspection. Pick the answer that describes the observation, explains why it matters and refers it. → Boilers, heat pumps and air conditioning
- Two wrong answers recur: that adding vents will dry a crawl space in a humid climate, and that a bath fan may discharge into a well-ventilated attic. Both move moisture to a cold surface instead of removing it. → Attic ventilation, crawl spaces and exhaust ducts
Chapter 6
Standards, Ethics & Reporting
Key takeaways
- A home inspection is a visual, non-invasive look at readily accessible installed systems, not a code ruling, a warranty or an engineering study. → What a home inspection is and is not
- A material defect may significantly lower value or pose an unreasonable risk to people, and age alone does not make something defective. → Material defects and how to classify findings
- When something is not inspected, the report says so and gives the reason, and it names the method used, such as viewing from the eaves. → Writing the report: methods, limits and wording
- A suspected gas leak is told to the client and occupants at once and placed conspicuously in the report. → Exclusions, environmental hazards and immediate dangers
- The signed agreement comes before any work, the report goes only to the client unless the client consents, and referrals name a trade rather than a company. → Agreements, confidentiality and conflicts of interest
Common trap
- A common wrong answer reads not required to as prohibited from. The standards set a floor on scope, not a ceiling, so a properly qualified inspector may add a service when it is agreed in writing and done competently. → What a home inspection is and is not
- The three classic over-claims in wrong answers are a repair cost estimate, a diagnosed cause the inspector never observed, and a prediction of remaining life. The two classic under-claims are omitting an item that could not be inspected and calling an unseen area satisfactory. → Writing the report: methods, limits and wording
Quick reference
| Finding | Classification |
|---|---|
| 22-year-old furnace that runs normally with no warning signs | Report its age and condition; not a defect on age alone |
| Leaf-packed gutter and downspout at the foundation | Maintenance item, reportable because of its implication for the foundation |
| Scuffed, faded interior door | Cosmetic |