Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Structure & Foundation0/5
    1. Footings, soil movement and foundation crack patterns
    2. Water below grade and in crawl spaces
    3. Load path, columns and floor framing
    4. Roof framing: rafters, ridges and trusses
    5. Decay and wood-destroying organisms
  2. 2.Roofing, Exterior & Site0/5
    1. Roof coverings: how they keep water out and how they fail
    2. Flashings and roof penetrations
    3. Roof drainage, ice dams and chimney tops
    4. Walls, cladding and windows as drained assemblies
    5. Decks, grading and retaining walls
  3. 3.Electrical Systems0/5
    1. Service entrance and capacity
    2. Grounding, bonding and the neutral
    3. Inside the panel: overcurrent protection and terminations
    4. Ground-fault, arc-fault and receptacle testing
    5. Older wiring, workmanship defects and generators
  4. 4.Plumbing Systems0/4
    1. Water supply and piping materials
    2. Traps, vents and drain defects
    3. Water heaters, relief valves and gas connections
    4. Cross-connections, backflow and fixture leaks
  5. 5.HVAC, Insulation & Ventilation0/5
    1. Furnace combustion safety
    2. Venting, draft and house depressurization
    3. Boilers, heat pumps and air conditioning
    4. Insulation, air barriers and vapor retarders
    5. Attic ventilation, crawl spaces and exhaust ducts
  6. 6.Standards, Ethics & Reporting0/5
    1. What a home inspection is and is not
    2. Material defects and how to classify findings
    3. Writing the report: methods, limits and wording
    4. Exclusions, environmental hazards and immediate dangers
    5. Agreements, confidentiality and conflicts of interest
Saved in this browser. Move it to another device →
← Plumbing Systems

Chapter 4 · Lesson 3 of 4

Water heaters, relief valves and gas connections

1 min read

The temperature-and-pressure relief valve discharge line exists so a relieving valve can dump scalding water safely and so someone notices. Anything that can block it or hold water defeats that purpose.

Example: a line that rises above the tank, reduces at a coupling, passes through a shutoff valve and ends in threads has four defects, the rise, the reduction, the valve and the threaded end.

A valve with no discharge pipe at all, open at head height, is a scald hazard. In every case the inspector reports and refers; lifting the test lever on an old valve is excluded and can leave it leaking.

A draft hood should pull room air inward once the vent is warm. If, several minutes into a burn, warm moist air and smoke push outward at the relief opening, and rust stains the hood and tank top, the heater is spilling combustion products that can carry carbon monoxide.

Report it at once. For gas connections, a flexible appliance connector must stay a single exposed length; running it through a wall, floor or cabinet side hides it and lets it chafe. Sediment traps are not expected at every appliance, and dryers and ranges are usual exceptions.

Check yourself

1. At a storage water heater the temperature-and-pressure relief valve discharges into a pipe that first rises above the top of the tank, then turns down, is reduced in diameter at a coupling, passes through a shutoff valve, and ends in a threaded fitting. Which statement best describes the problem?

2. After the burner of an atmospherically vented gas water heater has been running for several minutes, the inspector feels warm, moist air at the relief opening of the draft hood and sees smoke drawn outward into the room rather than up the vent. There is rust on the hood and on the top of the tank. What does this indicate?

Facts checked 2026-11-15 · Sources: National Home Inspector Examination (EBPHI), InterNACHI Home Inspection Standards of Practice