Chapters0/29 ▾
Chapter 5 · Lesson 4 of 5
Insulation, air barriers and vapor retarders
1 min read
Insulation resists conduction and nothing else; air moving through or around it carries heat right past. A bonus room over a garage shows the failure: batts stuffed into knee-wall studs with nothing on the attic side, floor joist cavities open to the attic, and no insulation over the garage.
Attic air washes under the floor and through the fibers, so the insulation cannot reach its rated value. The fix in principle is to block the cavity ends and keep a continuous air barrier in contact with the insulation all the way around the room.
Vapor diffuses from warm, humid air toward the cold side. In a heating-dominated climate, that means from inside to outside in winter, so a vapor retarder goes toward the warm-in-winter interior face.
In a hot, humid climate an interior low-permeance retarder becomes a liability, and retarders on both faces trap moisture with no way to dry. Air leaks carry far more moisture than diffusion, so air sealing matters even more than the retarder.
Crumbling white fibrous wrap on old furnace ducts is described as a suspected asbestos-containing material in damaged condition. Only a lab can confirm it, so the inspector advises not disturbing it and refers to a qualified specialist rather than sampling or taping it.
Check yourself
1. A bonus room over a garage is cold in winter and hot in summer. In the attic space behind the room the inspector finds fibreglass batts stuffed between the knee wall studs with nothing covering their attic side, the floor joist cavities under the room open to the attic at the base of the knee wall, and no insulation in the floor over the garage. Which statement best explains the performance problem?
2. In a heating-dominated climate, why is a vapour retarder normally placed toward the interior face of an insulated wall assembly, and what companion measure matters even more?
Facts checked 2026-11-15 · Sources: National Home Inspector Examination (EBPHI), InterNACHI Home Inspection Standards of Practice