Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Structure & Foundation0/5
    1. Footings, soil movement and foundation crack patterns
    2. Water below grade and in crawl spaces
    3. Load path, columns and floor framing
    4. Roof framing: rafters, ridges and trusses
    5. Decay and wood-destroying organisms
  2. 2.Roofing, Exterior & Site0/5
    1. Roof coverings: how they keep water out and how they fail
    2. Flashings and roof penetrations
    3. Roof drainage, ice dams and chimney tops
    4. Walls, cladding and windows as drained assemblies
    5. Decks, grading and retaining walls
  3. 3.Electrical Systems0/5
    1. Service entrance and capacity
    2. Grounding, bonding and the neutral
    3. Inside the panel: overcurrent protection and terminations
    4. Ground-fault, arc-fault and receptacle testing
    5. Older wiring, workmanship defects and generators
  4. 4.Plumbing Systems0/4
    1. Water supply and piping materials
    2. Traps, vents and drain defects
    3. Water heaters, relief valves and gas connections
    4. Cross-connections, backflow and fixture leaks
  5. 5.HVAC, Insulation & Ventilation0/5
    1. Furnace combustion safety
    2. Venting, draft and house depressurization
    3. Boilers, heat pumps and air conditioning
    4. Insulation, air barriers and vapor retarders
    5. Attic ventilation, crawl spaces and exhaust ducts
  6. 6.Standards, Ethics & Reporting0/5
    1. What a home inspection is and is not
    2. Material defects and how to classify findings
    3. Writing the report: methods, limits and wording
    4. Exclusions, environmental hazards and immediate dangers
    5. Agreements, confidentiality and conflicts of interest
Saved in this browser. Move it to another device →
← Plumbing Systems

Chapter 4 · Lesson 2 of 4

Traps, vents and drain defects

1 min read

The trap holds a water seal that keeps sewer gas out of the room. The vent protects that seal. Water falling down a drain creates negative pressure behind it and positive pressure ahead of it, and the vent connects the drain to outside air so neither pressure can pull or push the seal out. Unvented fixtures gurgle and drain slowly.

  • Siphonage: the falling water pulls the seal out, as in an unvented S-trap whose outlet drops straight into the floor.
  • Back pressure: positive pressure in the drain blows the seal out.
  • Evaporation: the seal dries out in a fixture that is rarely used.
  • Capillary action: a rag or hair hanging over the trap dip wicks the water out, even in a fixture used daily.

Two other drain defects appear often. A double-trapped fixture, with a P-trap under the cabinet and a second trap below the floor, locks a pocket of air between two seals, so the sink drains slowly and gurgles; a trap is never a vent.

Corrugated flexible tubing used as a trap arm catches grease and solids in its ridges, cannot be cleared with a cable, and sags into low spots that hold waste. Recommend smooth, sloped, supported pipe.

Check yourself

1. A lavatory that is used every day gives off a persistent sewer odour. Inside the trap the inspector finds a length of rag-like debris hanging over the trap dip and down the outlet leg, and the trap is only partly filled. Which mechanism has emptied the seal?

2. Which statement best describes the function a vent performs for a fixture trap in a drain, waste and vent system?

Facts checked 2026-11-15 · Sources: National Home Inspector Examination (EBPHI), InterNACHI Home Inspection Standards of Practice