Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Structure & Foundation0/5
    1. Footings, soil movement and foundation crack patterns
    2. Water below grade and in crawl spaces
    3. Load path, columns and floor framing
    4. Roof framing: rafters, ridges and trusses
    5. Decay and wood-destroying organisms
  2. 2.Roofing, Exterior & Site0/5
    1. Roof coverings: how they keep water out and how they fail
    2. Flashings and roof penetrations
    3. Roof drainage, ice dams and chimney tops
    4. Walls, cladding and windows as drained assemblies
    5. Decks, grading and retaining walls
  3. 3.Electrical Systems0/5
    1. Service entrance and capacity
    2. Grounding, bonding and the neutral
    3. Inside the panel: overcurrent protection and terminations
    4. Ground-fault, arc-fault and receptacle testing
    5. Older wiring, workmanship defects and generators
  4. 4.Plumbing Systems0/4
    1. Water supply and piping materials
    2. Traps, vents and drain defects
    3. Water heaters, relief valves and gas connections
    4. Cross-connections, backflow and fixture leaks
  5. 5.HVAC, Insulation & Ventilation0/5
    1. Furnace combustion safety
    2. Venting, draft and house depressurization
    3. Boilers, heat pumps and air conditioning
    4. Insulation, air barriers and vapor retarders
    5. Attic ventilation, crawl spaces and exhaust ducts
  6. 6.Standards, Ethics & Reporting0/5
    1. What a home inspection is and is not
    2. Material defects and how to classify findings
    3. Writing the report: methods, limits and wording
    4. Exclusions, environmental hazards and immediate dangers
    5. Agreements, confidentiality and conflicts of interest
Saved in this browser. Move it to another device →
← Roofing, Exterior & Site

Chapter 2 · Lesson 3 of 5

Roof drainage, ice dams and chimney tops

1 min read

Roof drainage is a chain. A gutter must fall toward its outlet or it holds water and debris; edge flashing must carry water from the roof into the gutter or it wicks back onto the fascia; and the downspout must discharge away from the building or it simply delivers the whole roof's water to the foundation backfill.

A back-pitched gutter, a soft fascia and a downspout at the wall are three separate reportable findings.

Ice dams are diagnosed from the snow. Example: after a snowfall the roof over the heated rooms is bare while snow still sits on the overhang, with a ridge of ice and icicles at the eave.

Heat and air leaking from the house melted the snow above the warm deck, and the water refroze over the cold overhang, backing up under the laps. Heat cable only melts a channel through the symptom; the durable fix is air sealing, insulation and balanced attic ventilation, with an eave ice barrier as protection.

A thin mortar wash on top of a chimney cracks and lets water in, and freeze-thaw cycles then flake the brick faces and erode the joints. The durable detail is a cast, sloped crown that overhangs with a drip edge, plus a rain cap.

A chimney leaning away from the house, with a wedge-shaped gap, is a potential collapse hazard: report it, advise against use until evaluated, and refer to a structural professional.

Check yourself

1. After a snowfall, a house shows bare, melted roof over the main heated area but intact snow over the eave overhang, a thick ridge of ice at the eave with long icicles, and fresh staining on the top-floor ceiling near the exterior wall. What is the mechanism, and what is the durable correction?

2. An inspector finds gutters that hold standing water at the end farthest from the downspout, dark water staining and softened wood on the fascia directly behind the gutter, and downspouts that discharge onto the soil immediately at the foundation wall. Which statement best captures these findings?

Facts checked 2026-11-15 · Sources: National Home Inspector Examination (EBPHI), InterNACHI Home Inspection Standards of Practice

Home Inspector Practice Test (NHIE) cheat sheet: every key fact on one page →