Furnace combustion safety
1 min read
When the blower starts it pressurizes the air side of the furnace. If the heat exchanger is breached, that air leaks into the burner side and disturbs the flame, which shifts and turns yellow. Rust flakes on the burners and soot are part of the same evidence.
A visual look can never rule a heat exchanger in or out, so the report describes what was seen, explains the carbon monoxide significance and refers to a heating contractor. Dismantling panels or shutting off the gas at the meter is beyond the inspector's role.
- Flame rollout: flame escapes forward out of the burner opening and scorches nearby wiring because the heat exchanger or vent is blocked or the burners lack combustion air. It is a fire and carbon monoxide hazard.
- Flame proving: if the burners light and then go out after a few seconds, with lockout after three tries, the flame sensor is not confirming flame, so the control closes the gas valve to keep raw gas out of the combustion chamber.
- Combustion air: a furnace and water heater in a small sealed closet with a weatherstripped door run short of oxygen, burn incompletely and can reverse their vents. The remedy in principle is permanent openings to enough interior volume or to outdoors.
Check yourself
1. Scorching and melted wire insulation are visible on the outside of a gas furnace's burner compartment, and when the burners fire, flame briefly escapes forward out of the compartment opening. Which statement best describes this finding?
2. During a furnace inspection the inspector sees rust flakes on the burners, soot around the burner compartment, and a burner flame that shifts and turns yellow the moment the blower starts. What is the appropriate response?