Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Structure & Foundation0/5
    1. Footings, soil movement and foundation crack patterns
    2. Water below grade and in crawl spaces
    3. Load path, columns and floor framing
    4. Roof framing: rafters, ridges and trusses
    5. Decay and wood-destroying organisms
  2. 2.Roofing, Exterior & Site0/5
    1. Roof coverings: how they keep water out and how they fail
    2. Flashings and roof penetrations
    3. Roof drainage, ice dams and chimney tops
    4. Walls, cladding and windows as drained assemblies
    5. Decks, grading and retaining walls
  3. 3.Electrical Systems0/5
    1. Service entrance and capacity
    2. Grounding, bonding and the neutral
    3. Inside the panel: overcurrent protection and terminations
    4. Ground-fault, arc-fault and receptacle testing
    5. Older wiring, workmanship defects and generators
  4. 4.Plumbing Systems0/4
    1. Water supply and piping materials
    2. Traps, vents and drain defects
    3. Water heaters, relief valves and gas connections
    4. Cross-connections, backflow and fixture leaks
  5. 5.HVAC, Insulation & Ventilation0/5
    1. Furnace combustion safety
    2. Venting, draft and house depressurization
    3. Boilers, heat pumps and air conditioning
    4. Insulation, air barriers and vapor retarders
    5. Attic ventilation, crawl spaces and exhaust ducts
  6. 6.Standards, Ethics & Reporting0/5
    1. What a home inspection is and is not
    2. Material defects and how to classify findings
    3. Writing the report: methods, limits and wording
    4. Exclusions, environmental hazards and immediate dangers
    5. Agreements, confidentiality and conflicts of interest
Saved in this browser. Move it to another device →
← Plumbing Systems

Chapter 4 · Lesson 1 of 4

Water supply and piping materials

1 min read

The inspector describes whether the supply is public or private and reports the visible condition of accessible piping.

With a private well, the well, the pump and water quality are excluded, and the report says so. The standard functional flow check is to run two fixtures at once: a noticeable drop at the first fixture is an observed condition to report and refer to a plumber. Measuring pressure adequacy or sizing pipe is excluded.

Material and findingMechanism
Old galvanized steel, weak flow at the farthest fixtureInternal rust and scale, cumulative along the run
Copper, pinholes on elbows just past a partly closed valveErosion corrosion from high velocity and turbulence
PEX in direct sunlight at a crawl-space ventUltraviolet light embrittles the polymer
Copper joined straight to galvanized, heavy corrosion at the jointGalvanic corrosion; a dielectric fitting breaks the circuit

Grey flexible plastic supply pipe with insert fittings and crimp rings has a history of joint failures. The report describes what was seen, mentions that history and recommends a plumber. It does not positively identify the material, predict a failure date or cut out a sample, because a visual inspection is never destructive.

Corrosion questions turn on location. Erosion damage clusters at elbows and just past restrictions, galvanic damage sits at the joint between dissimilar metals, and rust buildup lines the whole bore of old galvanized pipe.

Check yourself

1. In a copper water distribution system the inspector finds repeated pinhole leaks and thin spots on the outside of elbows immediately downstream of a partly closed valve, with blue-green staining below them. Which mechanism is the best explanation?

2. In a crawl space the inspector observes flexible grey plastic water supply piping joined with plastic insert fittings and metal crimp rings, a material historically associated with failures at and near the joints. What is the appropriate handling of this observation?

Facts checked 2026-11-15 · Sources: National Home Inspector Examination (EBPHI), InterNACHI Home Inspection Standards of Practice