Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Structure & Foundation0/5
    1. Footings, soil movement and foundation crack patterns
    2. Water below grade and in crawl spaces
    3. Load path, columns and floor framing
    4. Roof framing: rafters, ridges and trusses
    5. Decay and wood-destroying organisms
  2. 2.Roofing, Exterior & Site0/5
    1. Roof coverings: how they keep water out and how they fail
    2. Flashings and roof penetrations
    3. Roof drainage, ice dams and chimney tops
    4. Walls, cladding and windows as drained assemblies
    5. Decks, grading and retaining walls
  3. 3.Electrical Systems0/5
    1. Service entrance and capacity
    2. Grounding, bonding and the neutral
    3. Inside the panel: overcurrent protection and terminations
    4. Ground-fault, arc-fault and receptacle testing
    5. Older wiring, workmanship defects and generators
  4. 4.Plumbing Systems0/4
    1. Water supply and piping materials
    2. Traps, vents and drain defects
    3. Water heaters, relief valves and gas connections
    4. Cross-connections, backflow and fixture leaks
  5. 5.HVAC, Insulation & Ventilation0/5
    1. Furnace combustion safety
    2. Venting, draft and house depressurization
    3. Boilers, heat pumps and air conditioning
    4. Insulation, air barriers and vapor retarders
    5. Attic ventilation, crawl spaces and exhaust ducts
  6. 6.Standards, Ethics & Reporting0/5
    1. What a home inspection is and is not
    2. Material defects and how to classify findings
    3. Writing the report: methods, limits and wording
    4. Exclusions, environmental hazards and immediate dangers
    5. Agreements, confidentiality and conflicts of interest
Saved in this browser. Move it to another device →
← Roofing, Exterior & Site

Chapter 2 · Lesson 5 of 5

Decks, grading and retaining walls

1 min read

Many deck collapses start at the ledger, the board that carries the deck's load, including people, into the house.

Common nails and generic deck screws are loaded in withdrawal and can pull out progressively, and a ledger with no flashing above it stays wet and decays the wood it bears on. That combination is reported as a safety defect, with correction by a qualified contractor before use.

Under the deck, sound framing transfers load by direct bearing: the beam should sit on top of the post or in a notch, with a metal connector. A beam nailed to the side of each post is hanging on a few nails.

Grading follows the same chain as roof drainage. A downspout at the wall, soil sloping toward the house and mulch piled above the siding line keep backfill saturated, and water moves through the foundation, leaving efflorescence inside.

The fix starts at the top: discharge roof water well away and slope the ground away from the foundation. A retaining wall that bulges, leans forward and has no visible weeps behind saturated soil is losing to hydrostatic pressure; report the movement and the collapse hazard and refer to an engineer.

Mulch or soil piled above the bottom of the siding also creates earth-to-cladding contact that wicks water and invites decay and insects, so it is noted for correction along with the grading.

Check yourself

1. An attached deck ledger is fastened to the house rim area with common nails and coated deck screws, and there is no flashing above the ledger. How should the inspector treat this?

2. A basement wall shows a white powdery deposit and damp staining along its base. Outside, the soil slopes back toward the house, mulch is piled above the bottom edge of the siding, and a downspout discharges at the wall. Which answer traces the complete path by which surface water reaches the basement?

Facts checked 2026-11-15 · Sources: National Home Inspector Examination (EBPHI), InterNACHI Home Inspection Standards of Practice