Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Structure & Foundation0/5
    1. Footings, soil movement and foundation crack patterns
    2. Water below grade and in crawl spaces
    3. Load path, columns and floor framing
    4. Roof framing: rafters, ridges and trusses
    5. Decay and wood-destroying organisms
  2. 2.Roofing, Exterior & Site0/5
    1. Roof coverings: how they keep water out and how they fail
    2. Flashings and roof penetrations
    3. Roof drainage, ice dams and chimney tops
    4. Walls, cladding and windows as drained assemblies
    5. Decks, grading and retaining walls
  3. 3.Electrical Systems0/5
    1. Service entrance and capacity
    2. Grounding, bonding and the neutral
    3. Inside the panel: overcurrent protection and terminations
    4. Ground-fault, arc-fault and receptacle testing
    5. Older wiring, workmanship defects and generators
  4. 4.Plumbing Systems0/4
    1. Water supply and piping materials
    2. Traps, vents and drain defects
    3. Water heaters, relief valves and gas connections
    4. Cross-connections, backflow and fixture leaks
  5. 5.HVAC, Insulation & Ventilation0/5
    1. Furnace combustion safety
    2. Venting, draft and house depressurization
    3. Boilers, heat pumps and air conditioning
    4. Insulation, air barriers and vapor retarders
    5. Attic ventilation, crawl spaces and exhaust ducts
  6. 6.Standards, Ethics & Reporting0/5
    1. What a home inspection is and is not
    2. Material defects and how to classify findings
    3. Writing the report: methods, limits and wording
    4. Exclusions, environmental hazards and immediate dangers
    5. Agreements, confidentiality and conflicts of interest
Saved in this browser. Move it to another device →
← Structure & Foundation

Chapter 1 · Lesson 3 of 5

Load path, columns and floor framing

1 min read

Every load in a house has to travel without a break from roof to rafters or trusses, to walls and headers, to joists, to girders and columns, to foundation walls and footings, and finally to the soil.

The exam tests this by describing a missing link: a remodel post that lands on the floor over ordinary joists with nothing beneath it, or a girder supported by a post that is not fastened top or bottom and sits on the slab instead of a footing. A slab is not a footing.

Notches and holes are judged by bending stress, not by memorized fractions. At mid-span the bottom fibers of a joist are in maximum tension and the top fibers in compression, while wood near mid-depth carries little stress.

A notch in the bottom edge at mid-span removes the most stressed wood and adds a sharp corner where cracks start, so it is far worse than a round hole bored near the middle of the depth.

A springy floor with no visible damage is still reportable as a stiffness and serviceability concern. The right report describes the bounce, recommends evaluation, and notes that a visual inspection does not determine whether framing sizes and spans are adequate. Calling the joists undersized or specifying sistering is engineering, not inspection.

Check yourself

1. Two identical floor joists of the same span have each had material removed at mid-span: one has a notch cut into its bottom edge, the other has a round hole bored near mid-depth. Why is the notch the greater structural concern?

2. A floor feels noticeably springy underfoot, but the visible joists and girder show no sagging, cracking, decay, or loss of bearing. What is the best way for the inspector to handle this?

Facts checked 2026-11-15 · Sources: National Home Inspector Examination (EBPHI), InterNACHI Home Inspection Standards of Practice