Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/29 ▾
  1. 1.Structure & Foundation0/5
    1. Footings, soil movement and foundation crack patterns
    2. Water below grade and in crawl spaces
    3. Load path, columns and floor framing
    4. Roof framing: rafters, ridges and trusses
    5. Decay and wood-destroying organisms
  2. 2.Roofing, Exterior & Site0/5
    1. Roof coverings: how they keep water out and how they fail
    2. Flashings and roof penetrations
    3. Roof drainage, ice dams and chimney tops
    4. Walls, cladding and windows as drained assemblies
    5. Decks, grading and retaining walls
  3. 3.Electrical Systems0/5
    1. Service entrance and capacity
    2. Grounding, bonding and the neutral
    3. Inside the panel: overcurrent protection and terminations
    4. Ground-fault, arc-fault and receptacle testing
    5. Older wiring, workmanship defects and generators
  4. 4.Plumbing Systems0/4
    1. Water supply and piping materials
    2. Traps, vents and drain defects
    3. Water heaters, relief valves and gas connections
    4. Cross-connections, backflow and fixture leaks
  5. 5.HVAC, Insulation & Ventilation0/5
    1. Furnace combustion safety
    2. Venting, draft and house depressurization
    3. Boilers, heat pumps and air conditioning
    4. Insulation, air barriers and vapor retarders
    5. Attic ventilation, crawl spaces and exhaust ducts
  6. 6.Standards, Ethics & Reporting0/5
    1. What a home inspection is and is not
    2. Material defects and how to classify findings
    3. Writing the report: methods, limits and wording
    4. Exclusions, environmental hazards and immediate dangers
    5. Agreements, confidentiality and conflicts of interest
Saved in this browser. Move it to another device →
← Electrical Systems

Chapter 3 · Lesson 5 of 5

Older wiring, workmanship defects and generators

1 min read

Knob-and-tube wiring was designed to be cooled by free air around two separated conductors. Burying it under blown-in insulation traps heat and speeds the breakdown of insulation that is already old and brittle, and the system has no equipment grounding conductor.

Solid aluminum branch wiring fails at the terminations: aluminum expands more than the brass and steel it is clamped to and slowly deforms under pressure, so joints loosen, oxidize and heat. Warm cover plates and flickering lights are the clues, and the accepted remedies are listed methods rated for aluminum at each connection.

Workmanship findings are judged by what protects people. Splices belong inside an accessible covered box, cable must be supported and protected where it can be damaged, and an extension cord stapled to a wall is not permanent wiring. An unfinished basement gets no exemption.

The most serious single finding is a portable generator cord-connected to a branch circuit with no transfer equipment or interlock. Generator power can backfeed through the service, be stepped up by the utility transformer, and energize lines that workers believe are dead.

In each of these cases the inspector describes the condition and refers it to a qualified licensed electrician rather than judging code compliance or making the repair, since repairing a system you have just inspected is a conflict of interest.

Check yourself

1. A portable generator in the garage is connected to the house by a cord plugged into a receptacle on a general-purpose branch circuit, and there is no transfer equipment or breaker interlock at the panel. Why is this the most serious finding of the electrical inspection?

2. In the attic of an older home, the inspector observes knob-and-tube conductors running through the framing and now buried under blown-in loose-fill insulation. What is the principal mechanism that makes this condition reportable?

Facts checked 2026-11-15 · Sources: National Home Inspector Examination (EBPHI), InterNACHI Home Inspection Standards of Practice

Home Inspector Practice Test (NHIE) cheat sheet: every key fact on one page →