Cross-connections, backflow and fixture leaks
1 min read
A cross-connection is any arrangement that could let non-potable water into the drinking-water supply. A garden hose on a laundry-tub faucet with its end lying in the tub is a submerged outlet below the flood rim; if supply pressure drops, tub water can be siphoned back.
The basic protection is an air gap above the rim, or a vacuum breaker where an air gap is not practical.
| Backflow type | Cause | Example |
|---|---|---|
| Back-siphonage | Negative or reduced pressure on the supply side | Hose submerged in a tub |
| Backpressure | Downstream pressure higher than supply pressure | Boiler make-up water line; needs a listed backflow preventer, not just a check valve |
Fixture leaks are traced from evidence to cause without opening anything. A toilet that rocks, with odor and stained flooring at its base, points to a failed seal and possibly a damaged flange or subfloor; the extent cannot be judged without removing the fixture.
A stained ceiling under a bathroom with cracked shower grout and missing tub sealant is reported as a likely water path, with evaluation and repair recommended. Opening the ceiling or flood-testing the shower pan is outside a visual inspection.
Check yourself
1. A boiler make-up water line is connected to the potable water supply, and the boiler can operate at a pressure higher than the pressure in the house supply piping. Which statement best describes the hazard?
2. A garden hose is attached to the laundry-tub faucet and its free end lies in the bottom of the tub. Why is this a cross-connection, and what is the basic protection?