Chapter 5 · Lesson 5 of 5
Attic ventilation, crawl spaces and exhaust ducts
1 min read
Attic ventilation is a path, not a set of holes. In a vented attic, air must enter low at the eaves and leave high at the ridge. If blown insulation buries the soffit vents and there are no baffles, the ridge vent still pulls, and the easiest air left is warm, humid house air leaking through ceiling bypasses.
It condenses on cold sheathing and warms the deck unevenly, which feeds ice dams. A baffle in each rafter bay keeps the channel open while allowing full insulation over the top plate.
In a humid summer climate, a vented crawl space with bare soil condenses moisture on cool ducts because incoming air reaches its dew point, and more vents make it worse. The alternative is a sealed, conditioned crawl space with a ground vapor retarder. Exhaust ducts follow one rule: terminate outdoors.
A bath fan dumping into the attic frosts the nail points and stains the sheathing. A crushed ribbed plastic dryer duct collects lint beside a heat source, a fire hazard, so the exhaust should be smooth rigid metal to an outdoor termination with a backdraft damper and no screen.
Check yourself
1. Blown insulation in an attic has been pushed out over the top plates until it fills the space at the eaves, no baffles are present, and the roof has a continuous ridge vent. What is the most likely consequence?
2. In a humid summer climate a vented crawlspace with an exposed earth floor shows water droplets on the cool ductwork and dampness on the underside of the subfloor, and the problem is worst on the hottest, most humid days. What mechanism explains this, and what alternative approach addresses it?
Facts checked 2026-11-15 · Sources: National Home Inspector Examination (EBPHI), InterNACHI Home Inspection Standards of Practice