Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/24 ▾
← Inspections & Safety Requirements

Chapter 6 · Lesson 2 of 4

Wire rope removal from service

1 min read

OSHA 1926.1413 splits wire rope findings into two kinds. Some are fixed thresholds that mean removal as soon as they are reached. Others, such as kinking, crushing, unstranding, birdcaging, core failure, corrosion, heat damage and damaged end connections, require the competent person to judge whether a safety hazard exists and act on it.

  • Running rope: 6 randomly distributed broken wires in one rope lay, or 3 broken wires in one strand in one lay.
  • Rotation-resistant rope has its own, tighter count, including 2 randomly distributed broken wires in 6 rope diameters.
  • Standing rope has separate criteria, including breaks at end connections.
  • A diameter reduction of more than 5 percent from nominal takes the rope out of service; any prior contact with an energized power line means replacement, never repair.

Example: on a rope with a nominal diameter of 3/4 in (0.75 in), 5 percent is 0.0375 in, so a measured diameter below about 0.71 in means removal even if no broken wire is visible. Pay special attention at reverse bends, drum crossover and flange points, terminal ends and equalizer sheave sections, where damage concentrates or hides.

Check yourself

1. A running rope on a mobile crane shows randomly distributed broken wires. Under the OSHA construction crane standard, which finding requires the rope to be removed from service?

2. During a shift wire rope inspection a competent person finds birdcaging and crushing on a section of hoist rope. How does the OSHA construction crane standard treat that finding?

Facts checked 2026-11-15 · Sources: OSHA 29 CFR 1926.1412: Inspections, OSHA 29 CFR 1926.1413: Wire rope, inspection, OSHA 29 CFR 1926.1415: Safety devices

Crane Operator (NCCCO) cheat sheet: every key fact on one page →