Chapters0/24 ▾
Chapter 6 · Lesson 3 of 4
Safety devices, tagged equipment and cab documents
1 min read
OSHA 1926.1415 lists safety devices that must all work before operations begin: a crane level indicator, boom stops (except on derricks and hydraulic booms), jib stops when a jib is attached, foot pedal brake locks, an integral holding device or check valve on hydraulic outrigger and stabilizer jacks, rail clamps and rail stops where applicable, and a horn.
If one fails during work, the operator stops safely and the crane is out of service until it is fixed. There are no temporary measures and no repair window.
That is the key contrast with operational aids such as the load moment indicator, the boom angle indicator and the drum rotation indicator, which allow continued work for 7 or 30 calendar days under required temporary measures.
The anti two-block device is a Category I aid, not a safety device. Example: damaged boom stops found at start-up mean the crane does not work today, while a failed load moment indicator allows work if each load weight is determined and given to the operator before the lift.
- A crane tagged out of service is not started until an authorized person removes the tag, or until it is verified that no one is servicing it and repairs are complete.
- Load charts, recommended operating speeds, special hazard warnings, instructions and the operator's manual are readily available in the cab at all times.
Check yourself
1. Before operations begin, the crew discovers the crane's boom stops are damaged. Under the OSHA construction crane standard, what is required?
2. Which of the following is a safety device under the OSHA construction crane standard rather than an operational aid?
Facts checked 2026-11-15 · Sources: OSHA 29 CFR 1926.1412: Inspections, OSHA 29 CFR 1926.1413: Wire rope, inspection, OSHA 29 CFR 1926.1415: Safety devices
Crane Operator (NCCCO) cheat sheet: every key fact on one page →