Chapters0/23 ▾
Chapter 4 · Lesson 2 of 4
Fluid lines: flares, flareless fittings and flexible hose
1 min read
A good flare is smooth, concentric and even in wall thickness, with no cracks, splits, scratches or die marks.
Its outside diameter must be large enough to seat fully on the fitting cone but must not extend past the outside of the sleeve, because the sleeve has to bear evenly on the back of the flare. A split at the lip cannot be sealed by tightening; the flare is cut off and made again.
A flareless fitting depends on the sleeve biting into the tube during presetting. When a preset fitting is reinstalled, run the nut up by hand until torque rises sharply, then turn it about one-sixth turn, one flat, and never more than one-third turn.
Turning more collapses the tube behind the sleeve. Example: on a hex nut, one flat is 60 degrees of rotation, and the one-third-turn limit is two flats.
Flexible hose contracts in length and expands in diameter when pressurized, so it is installed with about 5 to 8 percent slack. A hose pulled tight would load its end fittings and the structure once the system comes up to pressure.
The lay line printed along the hose is a straightness reference: if it spirals after installation, the hose is twisted and must be reinstalled.
Check yourself
1. Which statement about installing a flexible hose assembly is true?
2. A 37-degree single flare has been formed on aluminum alloy tubing. Which condition shows that the flare was formed correctly?
Facts checked 2026-11-15 · Sources: FAA-S-ACS-1 Aviation Mechanic Airman Certification Standards, FAA Aircraft Handbooks and Manuals (FAA-H-8083-30B AMT Handbook, General), FAA AC 43.13-1B Acceptable Methods, Techniques, and Practices: Aircraft Inspection and Repair
FAA A&P Mechanic (General) cheat sheet: every key fact on one page →