A wire's current rating is set by the temperature its insulation can stand. Current heats the wire by I² × R, and a wire inside a bundle or conduit cannot shed that heat as well as a single wire in free air, so its rating is reduced.
The fuse or circuit breaker is chosen to protect the wire: it must open before the conductor overheats. Aircraft do not use automatic-reset breakers, because they would keep re-energizing a fault; a tripped breaker is reset by hand, and only once.
- Ammeter: goes in series and has very low internal resistance. Placed across a battery it acts as a short and burns out. Its range is extended with a shunt in parallel.
- Voltmeter: goes in parallel across the part being measured. Its range is extended with a multiplier resistor in series.
- Ohmmeter: supplies its own test current, so the circuit must be de-energized, and the part isolated so parallel paths do not make it read low.
Check yourself
1. How are the ranges of a moving-coil ammeter and a moving-coil voltmeter extended?
2. When a fuse or circuit breaker rating is selected for an aircraft circuit, what is the protective device chosen primarily to protect?
Facts checked 2026-11-15 · Sources: FAA-S-ACS-1 Aviation Mechanic Airman Certification Standards, FAA Aircraft Handbooks and Manuals (FAA-H-8083-30B Aviation Maintenance Technician Handbook, General)