Reading gauge pressures and locating components

1 min read

Pressure questions compare both gauges with the manufacturer's chart for the ambient temperature, usually at fast idle on max A/C. Read the pair together, because one gauge alone fits several causes.

For example, a high side well above the chart on its own could be air, overcharge or a dead condenser fan; if the fan is not turning, that is the first thing to fix.

Low sideHigh sideLikely cause
LowLowUndercharge: the evaporator is starved and there is too little vapor to build head pressure
Normal or highHighAir in the system, overcharge, or poor condenser airflow such as a dead fan
HighLowCompressor not pumping, such as leaking reed valves

Component location follows the metering device. An orifice tube is a fixed restriction that cannot regulate flow, so the accumulator sits on the low side after the evaporator to catch liquid before it reaches the compressor; it also stores refrigerant, holds desiccant and returns oil through a bleed hole.

In an expansion valve system, the receiver-drier sits on the high side after the condenser.

Check yourself

1. On a hot day the A/C blows only slightly cool air. At fast idle on max A/C, both the low-side and high-side readings are well below the manufacturer's pressure chart for that ambient temperature. What is the most likely cause?

2. In an orifice tube system, where is the accumulator located, and what is one of its jobs?

Facts checked 2026-11-16 · Sources: ASE: Official Automobile Study Guide (A7 Heating and Air Conditioning test specifications and task list), EPA: Section 609 Technician Training and Certification Programs, EPA: Unique Fittings and Label Colors (MVAC refrigerants)

ASE Automotive Technician cheat sheet: every key fact on one page →