Battery testing starts with state of charge. After removing surface charge and letting the battery rest, about 12.6 V means full and about 12.2 V means roughly half charged. A partly charged battery fails a load test even when it is healthy, so recharge first.
A common load test applies half the cold cranking rating for 15 seconds and expects at least 9.6 V at about 70 °F. Example: a 600 CCA battery is loaded to 300 A; if a fully charged battery falls below 9.6 V by the end, it lacks capacity and is replaced.
The CCA rating itself is the current a new, fully charged battery can deliver for 30 seconds at 0 °F while staying at or above 7.2 V, which is 1.2 V per cell.
- Slow crank with low starter current and high cranking voltage: something is limiting current, usually resistance in the cables, connections or ground.
- Slow crank with high current and low voltage: something is demanding current, such as a dragging starter or a tight engine.
- On vehicles that manage charging by battery type, register or reset the new battery, and replace an AGM battery with an AGM battery.
- A steady voltage far above normal with a sulfur smell and repeated battery failures points to a faulty regulator or a resistive voltage-sense circuit.
Check yourself
1. After surface charge is removed and the battery rests, open-circuit voltage measures 12.2 V at about 70 degrees F. What does that indicate and what should be done next?
2. A customer has replaced several batteries and reports a sulfur odor. System voltage measures a steady 15.8 V at idle and at speed with the lights on. What is the MOST likely cause?
Facts checked 2026-11-15 · Sources: ASE: Official Automobile Study Guide (A6 Electrical/Electronic Systems test specifications and task list), ASE: Automobile and Light Truck (A1-A9) tests
ASE Automotive Technician cheat sheet: every key fact on one page →