Chapter 6 · Lesson 2 of 5
Flushing, evacuation, charging and compressor oil
1 min read
A vacuum lowers system pressure so air is drawn out and moisture boils off as vapor. Solid particles do not boil, so after a compressor fails and sends debris through the system, evacuation alone leaves the debris in place.
The parts that can be flushed are flushed, and the parts that cannot are replaced: the accumulator or receiver-drier, the orifice tube or expansion valve, and multi-pass condensers.
When charging a running system with the compressor engaged, add refrigerant through the low-side port only.
The low side sits at suction pressure, below the pressure in the charging source, so the compressor draws refrigerant in. The high side is at discharge pressure, higher than the source, so refrigerant cannot flow in there and can be pushed back toward the hose and container.
Lubricant must match the compressor. A high-voltage electric compressor in a hybrid or EV is powered from the high-voltage battery, and its oil also insulates the motor windings.
Manufacturers specify a non-conductive oil, typically POE or a special PAG, and only the specified oil goes in. For example, if a technician injects standard PAG left over from a belt-driven R-134a job into a hybrid's electric compressor, the oil can lower insulation, creating a shock hazard and compressor damage, which is why dedicated equipment or oil injectors are used.
Check yourself
1. A compressor failure has sent metal debris through the system. Why is a long, deep evacuation alone not enough to clean it out?
2. A hybrid vehicle has a high-voltage electric A/C compressor. Which lubricant rule matters most when servicing it?
Facts checked 2026-11-16 · Sources: ASE: Official Automobile Study Guide (A7 Heating and Air Conditioning test specifications and task list), EPA: Section 609 Technician Training and Certification Programs, EPA: Unique Fittings and Label Colors (MVAC refrigerants)