Sterilization Methods Study Guide — Sterile Processing (CRCST)
34 free practice questions
Sterilization questions on the CRCST exam test whether you understand what a cycle actually proves. You need to know how steam kills, why trapped air is the main enemy, what each monitor can and cannot show, and when a load may be released. The rules below follow ANSI/AAMI ST79 for steam, ST41 and ST58 for low-temperature methods, and the CDC/HICPAC disinfection and sterilization guideline.
Key takeaways
- Saturated steam kills by coagulating and denaturing proteins, and any air left in the chamber or pack keeps steam from reaching the surface.
- The Bowie-Dick test checks only air removal, is run daily in an empty prewarmed chamber before the first load, and two failures take the sterilizer out of service.
- Only the biological indicator directly shows lethality; physical and chemical monitors show that conditions were met.
- Implant loads are held until the biological indicator is read, except for a documented emergency release on an exception form.
- A wet pack is contaminated and must be fully reprocessed, so loads are arranged and cooled to prevent condensate.
Lessons in this chapter
5 short lessons · 5 min read
- 1How steam kills and how air is removed1 min
- 2The daily air-removal (Bowie-Dick) test1 min
- 3Physical, chemical and biological monitoring1 min
- 4Release decisions: requalification, implants and immediate use1 min
- 5Loading, wet packs, cooling and low-temperature methods1 min
Facts checked 2026-11-15 · Sources: HSPA: Certified Registered Central Service Technician (CRCST) exam content outline, CDC/HICPAC: Guideline for Disinfection and Sterilization in Healthcare Facilities
Sterile Processing (CRCST) cheat sheet: every key fact on one page →Next chapter: Packaging & Sterile Storage →Practice questions based on the HSPA CRCST Certification Exam Content Outline, ANSI/AAMI ST79 sterility-assurance practice, and CDC/HICPAC disinfection and sterilization guidance. CRCST is a mark of the Healthcare Sterile Processing Association; this site is not affiliated with or endorsed by HSPA. Always follow the device manufacturer's written instructions for use, your facility's policies, and the current edition of the applicable standards. About the CRCST exam →