Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/41 ▾
  1. 1.Department Operations & Safety0/5
    1. The work environment: pressure, humidity, cleaning and workflow
    2. Attire, jewelry and traffic control
    3. Workplace safety: spills, chemicals and safe lifting
    4. Regulators, standards and the order of authority
    5. Training records, documentation and quality improvement tools
  2. 2.Decontamination & Cleaning0/5
    1. Point-of-use treatment and safe transport
    2. The decontamination room and personal protective equipment
    3. Manual cleaning: water, brushes and detergent
    4. Ultrasonic cleaners and washer-disinfectors
    5. Flexible endoscopes and automated reprocessors
  3. 3.Sterilization Methods0/5
    1. How steam kills and how air is removed
    2. The daily air-removal (Bowie-Dick) test
    3. Physical, chemical and biological monitoring
    4. Release decisions: requalification, implants and immediate use
    5. Loading, wet packs, cooling and low-temperature methods
  4. 4.Packaging & Sterile Storage0/4
    1. Inspecting and assembling instruments
    2. Wraps and wrapping techniques
    3. Peel pouches, rigid containers and labels
    4. Cooling, wet packs and sterile storage
  5. 5.Quality Assurance & Monitoring0/5
    1. Sterilizer records, lot control and traceability
    2. Releasing a load and handling implants
    3. Positive biological indicators, recalls and failure reports
    4. Shelf life, stock rotation and package inspection
    5. Instructions for use, loaners, competency and quality benchmarks
  6. 6.Infection Prevention0/5
    1. The chain of infection, Standard Precautions and hand hygiene
    2. Decontamination design, airflow and safe transport
    3. Sharps, PPE and exposure incidents
    4. The Spaulding classification and high-level disinfection
    5. Microbial resistance, soil, biofilm and prions
  7. 7.Storage, Inventory & Distribution0/4
    1. Replenishment systems and ordering
    2. Receiving in the break-out area
    3. Sterile storage, rotation and transport
    4. Tracking, recalls and inventory problems
  8. 8.Patient Care Equipment0/4
    1. Why patient care equipment is noncritical
    2. Cleaning, contact time and a clean work area
    3. Inspection and removal from service
    4. Preparing, storing, distributing and tracking
  9. 9.Professional Skills & Terminology0/4
    1. Procedure suffixes: what the surgeon will do
    2. Body-part roots and putting words together
    3. Protecting patient information under HIPAA
    4. Professional communication and teamwork
Saved in this browser. Move it to another device →
← Back

Study guide · Chapter 6 of 9

Infection Prevention Study Guide — Sterile Processing (CRCST)

30 free practice questions

Infection control questions on the CRCST exam ask why sterile processing works the way it does: why every soiled item is treated as infectious, why decontamination is a closed room, and how the level of processing is chosen for a device. Many items give a scene and ask for the correct action or the reason behind a rule. The rules below come from the CDC disinfection and sterilization guideline, ANSI/AAMI ST79 and the OSHA Bloodborne Pathogens Standard.

Key takeaways

  • Reprocessing a device breaks the chain of infection at the mode of transmission, because the instrument is the vehicle that would carry organisms to the next patient.
  • Decontamination is enclosed and kept at negative pressure, and items move one way only, from soiled to clean to sterile.
  • Contaminated sharps are moved with forceps, never with the hands, and any exposure is reported for free, confidential follow-up.
  • Spaulding assigns the level by what the device touches on that use: sterile tissue means sterilization, mucous membrane means at least high-level disinfection, intact skin means low-level disinfection.
  • Cleaning comes first because soil and biofilm shield organisms from the agent, and prions need a special protocol while C. difficile does not.

Lessons in this chapter

5 short lessons · 5 min read

  1. 1The chain of infection, Standard Precautions and hand hygiene1 min
  2. 2Decontamination design, airflow and safe transport1 min
  3. 3Sharps, PPE and exposure incidents1 min
  4. 4The Spaulding classification and high-level disinfection1 min
  5. 5Microbial resistance, soil, biofilm and prions1 min
View all questions & answers →

Facts checked 2026-11-15 · Sources: CDC: Guideline for Disinfection and Sterilization in Healthcare Facilities (2008), OSHA 29 CFR 1910.1030: Bloodborne Pathogens, HSPA: Certified Registered Central Service Technician (CRCST)

Sterile Processing (CRCST) cheat sheet: every key fact on one page →Next chapter: Storage, Inventory & Distribution →

Practice questions based on the HSPA CRCST Certification Exam Content Outline, ANSI/AAMI ST79 sterility-assurance practice, and CDC/HICPAC disinfection and sterilization guidance. CRCST is a mark of the Healthcare Sterile Processing Association; this site is not affiliated with or endorsed by HSPA. Always follow the device manufacturer's written instructions for use, your facility's policies, and the current edition of the applicable standards. About the CRCST exam →