Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/41 ▾
  1. 1.Department Operations & Safety0/5
    1. The work environment: pressure, humidity, cleaning and workflow
    2. Attire, jewelry and traffic control
    3. Workplace safety: spills, chemicals and safe lifting
    4. Regulators, standards and the order of authority
    5. Training records, documentation and quality improvement tools
  2. 2.Decontamination & Cleaning0/5
    1. Point-of-use treatment and safe transport
    2. The decontamination room and personal protective equipment
    3. Manual cleaning: water, brushes and detergent
    4. Ultrasonic cleaners and washer-disinfectors
    5. Flexible endoscopes and automated reprocessors
  3. 3.Sterilization Methods0/5
    1. How steam kills and how air is removed
    2. The daily air-removal (Bowie-Dick) test
    3. Physical, chemical and biological monitoring
    4. Release decisions: requalification, implants and immediate use
    5. Loading, wet packs, cooling and low-temperature methods
  4. 4.Packaging & Sterile Storage0/4
    1. Inspecting and assembling instruments
    2. Wraps and wrapping techniques
    3. Peel pouches, rigid containers and labels
    4. Cooling, wet packs and sterile storage
  5. 5.Quality Assurance & Monitoring0/5
    1. Sterilizer records, lot control and traceability
    2. Releasing a load and handling implants
    3. Positive biological indicators, recalls and failure reports
    4. Shelf life, stock rotation and package inspection
    5. Instructions for use, loaners, competency and quality benchmarks
  6. 6.Infection Prevention0/5
    1. The chain of infection, Standard Precautions and hand hygiene
    2. Decontamination design, airflow and safe transport
    3. Sharps, PPE and exposure incidents
    4. The Spaulding classification and high-level disinfection
    5. Microbial resistance, soil, biofilm and prions
  7. 7.Storage, Inventory & Distribution0/4
    1. Replenishment systems and ordering
    2. Receiving in the break-out area
    3. Sterile storage, rotation and transport
    4. Tracking, recalls and inventory problems
  8. 8.Patient Care Equipment0/4
    1. Why patient care equipment is noncritical
    2. Cleaning, contact time and a clean work area
    3. Inspection and removal from service
    4. Preparing, storing, distributing and tracking
  9. 9.Professional Skills & Terminology0/4
    1. Procedure suffixes: what the surgeon will do
    2. Body-part roots and putting words together
    3. Protecting patient information under HIPAA
    4. Professional communication and teamwork
Saved in this browser. Move it to another device →
← Infection Prevention

Chapter 6 · Lesson 4 of 5

The Spaulding classification and high-level disinfection

1 min read

Spaulding decides the minimum processing level by what a device will touch on that use, not by what the device is called. The device is always cleaned first.

CategoryContactMinimum processing
CriticalSterile tissue, joint spaces or the bloodstreamSterilization
SemicriticalMucous membranes or non-intact skinHigh-level disinfection
NoncriticalIntact skin onlyCleaning, then low-level disinfection at the labeled contact time

Example: one ultrasound transducer is used on intact skin in the morning and enters a sterile joint space in the afternoon. For the skin scan it is noncritical; for the joint it is critical and must be sterilized, and a probe cover does not lower that.

A rigid arthroscope in the knee is critical too, even though it is an endoscope. High-level disinfection destroys all microorganisms except large numbers of bacterial spores. A disinfectant basin is discarded when either its test strip fails or its labeled reuse period ends, whichever comes first.

Check yourself

1. The same ultrasound transducer is used on intact skin for a bedside scan and, in a later procedure, is introduced into a sterile joint space. Under the Spaulding classification, what does this mean?

2. A transesophageal echocardiography probe contacts the mucous membrane of the esophagus and does not enter sterile tissue. What does the Spaulding classification require for it?

Facts checked 2026-11-15 · Sources: CDC: Guideline for Disinfection and Sterilization in Healthcare Facilities (2008), OSHA 29 CFR 1910.1030: Bloodborne Pathogens, HSPA: Certified Registered Central Service Technician (CRCST)

Sterile Processing (CRCST) cheat sheet: every key fact on one page →