Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/41 ▾
  1. 1.Department Operations & Safety0/5
    1. The work environment: pressure, humidity, cleaning and workflow
    2. Attire, jewelry and traffic control
    3. Workplace safety: spills, chemicals and safe lifting
    4. Regulators, standards and the order of authority
    5. Training records, documentation and quality improvement tools
  2. 2.Decontamination & Cleaning0/5
    1. Point-of-use treatment and safe transport
    2. The decontamination room and personal protective equipment
    3. Manual cleaning: water, brushes and detergent
    4. Ultrasonic cleaners and washer-disinfectors
    5. Flexible endoscopes and automated reprocessors
  3. 3.Sterilization Methods0/5
    1. How steam kills and how air is removed
    2. The daily air-removal (Bowie-Dick) test
    3. Physical, chemical and biological monitoring
    4. Release decisions: requalification, implants and immediate use
    5. Loading, wet packs, cooling and low-temperature methods
  4. 4.Packaging & Sterile Storage0/4
    1. Inspecting and assembling instruments
    2. Wraps and wrapping techniques
    3. Peel pouches, rigid containers and labels
    4. Cooling, wet packs and sterile storage
  5. 5.Quality Assurance & Monitoring0/5
    1. Sterilizer records, lot control and traceability
    2. Releasing a load and handling implants
    3. Positive biological indicators, recalls and failure reports
    4. Shelf life, stock rotation and package inspection
    5. Instructions for use, loaners, competency and quality benchmarks
  6. 6.Infection Prevention0/5
    1. The chain of infection, Standard Precautions and hand hygiene
    2. Decontamination design, airflow and safe transport
    3. Sharps, PPE and exposure incidents
    4. The Spaulding classification and high-level disinfection
    5. Microbial resistance, soil, biofilm and prions
  7. 7.Storage, Inventory & Distribution0/4
    1. Replenishment systems and ordering
    2. Receiving in the break-out area
    3. Sterile storage, rotation and transport
    4. Tracking, recalls and inventory problems
  8. 8.Patient Care Equipment0/4
    1. Why patient care equipment is noncritical
    2. Cleaning, contact time and a clean work area
    3. Inspection and removal from service
    4. Preparing, storing, distributing and tracking
  9. 9.Professional Skills & Terminology0/4
    1. Procedure suffixes: what the surgeon will do
    2. Body-part roots and putting words together
    3. Protecting patient information under HIPAA
    4. Professional communication and teamwork
Saved in this browser. Move it to another device →
← Infection Prevention

Chapter 6 · Lesson 2 of 5

Decontamination design, airflow and safe transport

1 min read

Cleaning soiled instruments produces aerosols and splash, and the soiled items and the people handling them are contaminated. That is why decontamination is a separate, enclosed room with a pass-through, and why items move in one direction only: soiled to clean to sterile.

A physical barrier and one-way flow keep contamination from reaching instruments that are already clean. Reasons like noise, separate cycle records or holding a backlog are not the point.

The room is held at negative pressure compared with the areas around it, so air always moves into decontamination and never out. Example: a cart is propping the door open and the pressure monitor shows air flowing toward the clean corridor.

The technician clears the doorway so the door closes, notifies the supervisor and facilities, and documents the finding so the affected period can be reviewed. A fan in the doorway is a workaround, not a fix.

Soiled instruments travel in closed, leak-resistant containers. If a container is found leaking in a corridor, containment has failed: wearing protection, contain the leak, have the area cleaned and disinfected, and report the container so it is removed from service.

Check yourself

1. A cart is propping open the door between decontamination and the clean corridor, and the room's pressure monitor now shows air moving out of decontamination toward the clean side. What should the technician do?

2. A closed transport container of soiled instruments is found in the corridor with fluid leaking from one corner onto the floor. What is the correct response?

Facts checked 2026-11-15 · Sources: CDC: Guideline for Disinfection and Sterilization in Healthcare Facilities (2008), OSHA 29 CFR 1910.1030: Bloodborne Pathogens, HSPA: Certified Registered Central Service Technician (CRCST)

Sterile Processing (CRCST) cheat sheet: every key fact on one page →