Cleaning soiled instruments produces aerosols and splash, and the soiled items and the people handling them are contaminated. That is why decontamination is a separate, enclosed room with a pass-through, and why items move in one direction only: soiled to clean to sterile.
A physical barrier and one-way flow keep contamination from reaching instruments that are already clean. Reasons like noise, separate cycle records or holding a backlog are not the point.
The room is held at negative pressure compared with the areas around it, so air always moves into decontamination and never out. Example: a cart is propping the door open and the pressure monitor shows air flowing toward the clean corridor.
The technician clears the doorway so the door closes, notifies the supervisor and facilities, and documents the finding so the affected period can be reviewed. A fan in the doorway is a workaround, not a fix.
Soiled instruments travel in closed, leak-resistant containers. If a container is found leaking in a corridor, containment has failed: wearing protection, contain the leak, have the area cleaned and disinfected, and report the container so it is removed from service.
Check yourself
1. A cart is propping open the door between decontamination and the clean corridor, and the room's pressure monitor now shows air moving out of decontamination toward the clean side. What should the technician do?
2. A closed transport container of soiled instruments is found in the corridor with fluid leaking from one corner onto the floor. What is the correct response?