Quibank app: now on the App Store — free, works offline. Get the app ↗

Chapters0/41 ▾
  1. 1.Department Operations & Safety0/5
    1. The work environment: pressure, humidity, cleaning and workflow
    2. Attire, jewelry and traffic control
    3. Workplace safety: spills, chemicals and safe lifting
    4. Regulators, standards and the order of authority
    5. Training records, documentation and quality improvement tools
  2. 2.Decontamination & Cleaning0/5
    1. Point-of-use treatment and safe transport
    2. The decontamination room and personal protective equipment
    3. Manual cleaning: water, brushes and detergent
    4. Ultrasonic cleaners and washer-disinfectors
    5. Flexible endoscopes and automated reprocessors
  3. 3.Sterilization Methods0/5
    1. How steam kills and how air is removed
    2. The daily air-removal (Bowie-Dick) test
    3. Physical, chemical and biological monitoring
    4. Release decisions: requalification, implants and immediate use
    5. Loading, wet packs, cooling and low-temperature methods
  4. 4.Packaging & Sterile Storage0/4
    1. Inspecting and assembling instruments
    2. Wraps and wrapping techniques
    3. Peel pouches, rigid containers and labels
    4. Cooling, wet packs and sterile storage
  5. 5.Quality Assurance & Monitoring0/5
    1. Sterilizer records, lot control and traceability
    2. Releasing a load and handling implants
    3. Positive biological indicators, recalls and failure reports
    4. Shelf life, stock rotation and package inspection
    5. Instructions for use, loaners, competency and quality benchmarks
  6. 6.Infection Prevention0/5
    1. The chain of infection, Standard Precautions and hand hygiene
    2. Decontamination design, airflow and safe transport
    3. Sharps, PPE and exposure incidents
    4. The Spaulding classification and high-level disinfection
    5. Microbial resistance, soil, biofilm and prions
  7. 7.Storage, Inventory & Distribution0/4
    1. Replenishment systems and ordering
    2. Receiving in the break-out area
    3. Sterile storage, rotation and transport
    4. Tracking, recalls and inventory problems
  8. 8.Patient Care Equipment0/4
    1. Why patient care equipment is noncritical
    2. Cleaning, contact time and a clean work area
    3. Inspection and removal from service
    4. Preparing, storing, distributing and tracking
  9. 9.Professional Skills & Terminology0/4
    1. Procedure suffixes: what the surgeon will do
    2. Body-part roots and putting words together
    3. Protecting patient information under HIPAA
    4. Professional communication and teamwork
Saved in this browser. Move it to another device →
← Storage, Inventory & Distribution

Chapter 7 · Lesson 4 of 4

Tracking, recalls and inventory problems

1 min read

Manual counts on paper take a lot of labor and invite errors. Scanning and RFID systems show inventory in real time and can automate reordering, and RFID can report where a tagged one-of-a-kind device is right now. They do not replace package inspection or date checks.

A device's unique device identifier (UDI) has two parts: the device identifier is the fixed part that names the labeler and model, and the production identifier is the variable part that can hold the lot, serial number and expiration date. The FDA database holds only the device identifier.

FDA uses the word recall for both correction and removal, so a recall may mean inspecting or adjusting a device rather than sending it back. When a recall letter lists lots on your shelves, carry out the recalling firm's instructions right away and respond to the firm.

Other problems are handled by communication: tell the requesting area about a back order and confirm any substitute with it, and when a code cart's breakaway seal is broken, check and restock the cart before it returns to service.

Supplies hidden in unofficial spots outdate, get damaged and vanish from the records. Example: a notice directs removal of lots 4471 and 4480, and you hold 4480. Pull lot 4480 as the notice directs and send your response to the firm.

Check yourself

1. A manufacturer's recall letter arrives listing lot numbers, and two of those lots are on the department's shelves. According to FDA recall guidance, what should the department do?

2. A department still counts stock by hand and records it on paper. What does moving to an electronic system that uses scanning or RFID offer?

Facts checked 2026-11-15 · Sources: HSPA: CRCST certification and exam content outline, CDC/HICPAC: Guideline for Disinfection and Sterilization in Healthcare Facilities, FDA: Recalls, Corrections and Removals (Devices)

Sterile Processing (CRCST) cheat sheet: every key fact on one page →